Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LLG ENERGY SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LLG ENERGY SERVICES, LLC in 1851 N MERCURY AVE., ODESSA, TX 79763 (NAICS 213112). OSHA activity number 341537991.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LLG Energy Services, LLC for free Get an email when a new federal OSHA severe-injury report for LLG Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1851 N MERCURY AVE.
City
ODESSA
State
TX
ZIP
79763
Mailing
1851 N MERCURY AVE., ODESSA, TX 79763
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
26
Ownership type
A

3 citations on file for this inspection.

1910.109 D02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2016
Abate by
Aug 22, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.109(d)(2)(iii): Each motor vehicle used for transporting explosives was not equipped with a minimum of two extinguishers, each having a rating of at least 10-BC.  The employer did not ensure vehicles transporting explosives were equipped with at least two (2) fire extinguishers and exposed employees to explosion hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.184 D

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2016
Abate by
Aug 22, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:  The employer did not ensure wire rope slings were inspected prior to their use and exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.184 E03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2016
Abate by
Aug 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination:  The employer did not ensure a record for each alloy steel chain sling was kept and exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341537991.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.