RONCEVERTE, WV —
OSHA Inspection: ARCHITECTURAL WOOD, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARCHITECTURAL WOOD, LLC in 977 EDGAR AVENUE, RONCEVERTE, WV 24970 (NAICS 337110). OSHA activity number 341539468.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCHITECTURAL WOOD, LLC
- Site address
- 977 EDGAR AVENUE
- City
- RONCEVERTE
- State
- WV
- ZIP
- 24970
- Mailing
- 977 EDGAR AVENUE, RONCEVERTE, WV 24970
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 32
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.134 E01
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $3,741 · Current $3,741
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Finishing Area: On or about June 08, 2016, and times prior, employees were required to use half face respirators, such as but not limited to, 3M brand half face negative pressure air purifying respirators during spray painting White Conversion Varnish, which contains Formaldehyde. The employer did not conduct a medical evaluation on the employees.
Recent events (1)
- — Z (S) $3741
1910.134 C01
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Finishing Area: On or about June 08, 2016, and times prior, employees were required to use half face respirators, such as but not limited to, 3M brand half face negative pressure air purifying respirators during spray painting White Conversion Varnish, which contains Formaldehyde. The employer did not develop and implement a respiratory protection program for the employees.
Recent events (1)
- — Z (S) $0
1910.134 F02
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Finishing Area: On or about June 08, 2016, and times prior, employees were required to use half face respirators, such as but not limited to, 3M brand half face negative pressure air purifying respirators during spray painting White Conversion Varnish, which contains Formaldehyde. The employer did not conduct a fit test on the employees.
Recent events (1)
- — Z (S) $0
1910.134 H01 I
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition: (a) Finishing Area: On or about June 08, 2016, and times prior, employees were required to use half face respirators, such as but not limited to, 3M brand half face negative pressure air purifying respirators during spray painting White Conversion Varnish, which contains Formaldehyde. The employees respirators were not maintained in a sanitary condition.
Recent events (1)
- — Z (S) $0
1910.134 K01
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii): (a) Finishing Area: On or about June 08, 2016, and times prior, employees were required to use half face respirators, such as but not limited to, 3M brand half face negative pressure air purifying respirators during spray painting White Conversion Varnish, which contains Formaldehyde. The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii).
Recent events (1)
- — Z (S) $0
1910.147 C02 II
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $4,988 · Current $4,988
General-duty citation text
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which rendered the machine or equipment inoperative. (a) Fabrication Area: On or about June 01, 2016, and times prior, the electrical disconnect for the Shop Bot milling machine, 220 Volt three phase, was not locked out while the employee changed the milling bit.
Recent events (1)
- — Z (S) $4988
1910.147 C06 I
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) Fabrication Area: On or about June 01, 2016, and times prior, an employee conducts energy control procedures on equipment such as the Shop Bot milling machine, 220 Volt three phase, prior to changing out the milling bit. The employer has not conducted a periodic inspection of the energy control procedures.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Fabrication Area: On or about June 01, 2016, and times prior, the electrical disconnect for the Shop Bot milling machine, 220 Volt three phase, was blocked by a dust collector and various fabricated wood materials preventing employee access.
Recent events (1)
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Sep 13, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) Architectural Wood, LLC: On or about June 8, 2016, and times prior, the employer did not provide training to the employees on the new SDS (safety data sheets) and label formats on materials used.
Recent events (1)
- — Z (O) $0
More inspections at Architectural Wood, LLC
View Architectural Wood, LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341539468.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.