ARVADA, CO —
OSHA Inspection: AUTOMOTIVE TRANSMISSION SPECIALIST INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AUTOMOTIVE TRANSMISSION SPECIALIST INC. in 5293 WARD RD, UNIT 11, ARVADA, CO 80015 (NAICS 811111). OSHA activity number 341546455.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMOTIVE TRANSMISSION SPECIALIST INC.
- Site address
- 5293 WARD RD, UNIT 11
- City
- ARVADA
- State
- CO
- ZIP
- 80015
- Mailing
- 5293 WARD RD, UNIT 11, ARVADA, CO 80015
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 48
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $3,741 · Current $1,871 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about June 10, 2016, and at times prior, the employer did not ensure that employees required to wear a respirator while working in the spray booth were medically cleared to do so. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1871
- — Z (S) $3741
1910.134 F02
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) On or about June 10, 2016, and at times prior, the employer did not ensure that employees required to wear a respirator while working in the spray booth were fit tested to ensure proper fit of the respirator. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $6,236 · Current $3,118 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a) On or about June 10, 2016, and at times prior, the employer did not ensure that a power cord from the control box to the plug on a transmission flush cart was continuous where it had been spliced. Abatement note: Abatement documentation is required for this item and must include the gauge size of the cord where a repair was made during inspection. See Certification of Corrective Action Worksheet.
Recent events (2)
- — I (S) $3118
- — Z (S) $6236
1910.305 G02 III
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) On or about June 10, 2016, and at times prior, the employer did not ensure that proper strain relief was used on a transmission flush cart where the outer insulation had pulled away from the terminus. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): On or about June 10, 2016, and at times prior, the employer did not ensure that a transmission flush cart was inspected for damage or defects to the insulation of the power cord. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Automotive Transmission Specialist INC.
View Automotive Transmission Specialist INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341546455.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.