NIAGARA FALLS, NY —
OSHA Inspection: WASHINGTON MILLS ELECTRO MINERALS CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WASHINGTON MILLS ELECTRO MINERALS CORPORATION in 1801 BUFFALO AVENUE, NIAGARA FALLS, NY 14302 (NAICS 327910). OSHA activity number 341546554.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASHINGTON MILLS ELECTRO MINERALS CORPORATION
- Site address
- 1801 BUFFALO AVENUE
- City
- NIAGARA FALLS
- State
- NY
- ZIP
- 14302
- Mailing
- 1801 BUFFALO AVENUE, NIAGARA FALLS, NY 14302
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327910
- Employees
- 110
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 25, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $6,300 · Current $4,725 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 06/10/16, in the Receiving Maintenance Shop, when employees perform maintenance and servicing activities, such as repairing the motor on the overhead door, energy control procedures were not being utilized. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $4725
- — Z (S) $6300
1910.147 C06 I
- Issued
- Jul 25, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $4,500 · Current $3,375 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 06/10/16, in the Receiving Maintenance shop, employer did not conduct periodic inspections of the Lockout/Tagout procedures for machines such as, but not limited to: the Lift Master (Overhead door motor). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3375
- — Z (S) $4500
1910.303 F02
- Issued
- Jul 25, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $2,700 · Current $2,025 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about 06/10/16, adjacent to the Receiving Maintenance Shop, each circuit breaker in the electrical panel was not legibly marked to indicate its purpose. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2025
- — Z (S) $2700
More inspections at Washington Mills Electro Minerals Corporation
View Washington Mills Electro Minerals Corporation's full OSHA safety record →
More inspections in this industry (NAICS 327910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341546554.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.