Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A.R.E. ACCESSORIES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A.R.E. ACCESSORIES, LLC in 400 NAVE ROAD, MASSILLON, OH 44646 (NAICS 423140). OSHA activity number 341547057.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.R.E. Accessories, LLC — free Get an email when a new federal OSHA severe-injury report for A.R.E. Accessories, LLC is published. One employer, no account, unsubscribe in one click.
Site address
400 NAVE ROAD
City
MASSILLON
State
OH
ZIP
44646
Mailing
400 NAVE ROAD, MASSILLON, OH 44646
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423140
Employees
650
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 27, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about June 6, 2016, the employer did not conduct periodic inspections of hazardous energy control procedures at least annually to ensure the procedures and requirements to control of hazardous energy were being followed.  Hazardous energy includes, but not limited to; electric, pneumatic, hydraulic, and kinetic energy.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 27, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   On or about June 6, 2016, the employer did not ensure maintenance employees replacing the belts of the Gel Coat Source ventilation fan and electric motor, turned off and shut down the equipment using the established procedures, operated all of the energy isolating devices, and affixed lockout devices to the energy isolating devices.  Energy sources include, but not limited to; electric and kinetic power.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 F03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department or other group.   On or about June 6, 2016, the employer did not ensure two maintenance employees utilized group energy control procedures for the safe application, usage, and removal of hazardous energy control devices while replacing the belts of the Gel Coat Source ventilation fan and electric motor.  Energy sources include, but not limited to; electric and kinetic power.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View A.R.E. Accessories, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341547057.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.