MASSILLON, OH —
OSHA Inspection: A.R.E. ACCESSORIES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A.R.E. ACCESSORIES, LLC in 400 NAVE ROAD, MASSILLON, OH 44646 (NAICS 423140). OSHA activity number 341547057.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.R.E. ACCESSORIES, LLC
- Site address
- 400 NAVE ROAD
- City
- MASSILLON
- State
- OH
- ZIP
- 44646
- Mailing
- 400 NAVE ROAD, MASSILLON, OH 44646
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423140
- Employees
- 650
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jun 27, 2016
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about June 6, 2016, the employer did not conduct periodic inspections of hazardous energy control procedures at least annually to ensure the procedures and requirements to control of hazardous energy were being followed. Hazardous energy includes, but not limited to; electric, pneumatic, hydraulic, and kinetic energy.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
1910.147 D
- Issued
- Jun 27, 2016
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about June 6, 2016, the employer did not ensure maintenance employees replacing the belts of the Gel Coat Source ventilation fan and electric motor, turned off and shut down the equipment using the established procedures, operated all of the energy isolating devices, and affixed lockout devices to the energy isolating devices. Energy sources include, but not limited to; electric and kinetic power.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
1910.147 F03 I
- Issued
- Jun 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department or other group. On or about June 6, 2016, the employer did not ensure two maintenance employees utilized group energy control procedures for the safe application, usage, and removal of hazardous energy control devices while replacing the belts of the Gel Coat Source ventilation fan and electric motor. Energy sources include, but not limited to; electric and kinetic power.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at A.R.E. Accessories, LLC
View A.R.E. Accessories, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341547057.