Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: LANE MECHANICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LANE MECHANICAL, INC. in 515 INDUSTRIAL WAY N., DALLAS, GA 30132 (NAICS 332322). OSHA activity number 341551265.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lane Mechanical, INC. for free Get an email when a new federal OSHA severe-injury report for Lane Mechanical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
515 INDUSTRIAL WAY N.
City
DALLAS
State
GA
ZIP
30132
Mailing
515 INDUSTRIAL WAY N., DALLAS, GA 30132
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
18
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 12, 2016
Abate by
Nov 7, 2016
Penalty
Initial $3,029 · Current $1,817 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Throughout Facility - On or about 6/15/2016, employees were exposed to electrical shock hazards, in that a lockout/tagout program including machine specific procedures, employee training, and periodic inspections was not provided to employees while performing service and repairs on the Accurshear and Accurpress brake machines.
Recent events (2)
  • · I (S) $1817.4
  • · Z (S) $3029

1910.212 A03 II

Serious Gravity 5 3 instances 4 exposed
Issued
Oct 12, 2016
Penalty
Initial $3,029 · Current $1,817 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) Throughout Facility - On or about 6/15/2016, employees were exposed to caught-in hazards, in that point of operation guarding was not provided on the Accupress brake and heavy end iron worker machines while employees were assembling metal sheets and other components of kitchen equipment.
Recent events (2)
  • · I (S) $1817.4
  • · Z (S) $3029

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Oct 12, 2016
Abate by
Nov 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a) Welding Department - On or about 6/15/2016, employees were exposed to respiratory tract irritations, in that a respiratory protection program that included worksite specific procedures was not implemented while employees were welding stainless steel sheets.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 6 exposed
Issued
Oct 12, 2016
Abate by
Nov 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Throughout Facility - On or above 6/15/2016, employees were exposed to skin, eye and respiratory tract irritations, in that training and education was not provided to employees handling hazardous chemicals such as, but not limited to hexavalent chromium and propane.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Lane Mechanical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341551265.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.