2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TBC CONTRACTORS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TBC CONTRACTORS, LLC in 4022 MCKINLEY ST., NW, WASHINGTON, DC 20015 (NAICS 238350). OSHA activity number 341553071.

Watch TBC Contractors, LLC — free Get an email when a new federal OSHA severe-injury report for TBC Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4022 MCKINLEY ST., NW
City
WASHINGTON
State
DC
ZIP
20015
Mailing
3330 WOODBURN VILLAGE DR.. APT. 32, ANNANDALE, VA 22003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $2138.00
29 CFR 1926.403(b)(2):  Listed, labeled, or certified equipment were not installed and used in accordance with instructions included in the listing, labeling, or certification:  a)  Basement - On or about 05/20/2016, carpenters were exposed to a 120 volt electrical contact hazard from a outlet box which was left on the floor and not installed in a wall as its listing and labeling intended.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2138

1926.405 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(2):  In energized installations each outlet box did not have a cover, faceplate, or fixture canopy.   a)  Basement - On or about 05/20/2016, carpenters were exposed to a 120 volt electrical contact hazard from an electrical outlet box which was not provided with a faceplate or a similar suitable cover.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $2138.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  Second Floor - On or about 05/20/2016,  4 foot by 10 foot floor hole which served as an entrance to a set of stairs was not provided with a cover, standard guard rails, nets, or similar fall protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2138

1926.1052 B03

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3207.00 · Current $3207.00
29 CFR 1926.1052(b)(3): Treads for temporary service shall be made of wood or other solid material, but were not installed the full width and depth of the stair:   a)  First Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary wooden stairs having wooden stair treads which only covered 7 inches of the 9 inch stair treads.  b)  Second Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary wooden stairs having wooden stair treads which only covered 7 inches of the 9 inch stair treads.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $3207

1926.1052 C01 I

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(i): Stairways having greater than four risers shall have at least one handrail:   a)  First Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary stairs which had not been provided with a handrail.   b)  Second  Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary stairs which had not been provided with a handrail.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1052 C01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a)  First Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary wooden stairs having wooden stair treads which only covered 7 inches of the 9 inch stair treads.   b)  Second  Floor - On or about 05/20/2016, workers were exposed to a 10 foot fall from a set of temporary wooden stairs having wooden stair treads which only covered 7 inches of the 9 inch stair treads.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

MACY'S