ENGLEWOOD, CO —
OSHA Inspection: VALIERN COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VALIERN COMPANY in 4201 S NAVAJO ST, ENGLEWOOD, CO 80110 (NAICS 332999). OSHA activity number 341554061.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALIERN COMPANY
- Site address
- 4201 S NAVAJO ST
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80110
- Mailing
- 4201 S NAVAJO ST, ENGLEWOOD, CO 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 8
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.23 B01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.23(b)(1): 29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) On or about June 16, 2016, and at times prior, employees were exposed to fall hazards of eight feet or more where no guardrails or any other type of fall protection was in place at the opening to the upper level storage area. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2000
1910.24 H
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) On or about June 16, 2016, and at times prior, employees were exposed to fall hazards where the stairway to the upper storage area did not have any handrails in place. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about June 16, 2016, and at times prior, employees were exposed to amputation hazards where machine guarding was not provided in the following instances: 1. The Trajan Saw Works horizontal band saw, model 101, serial no. 790026, did not have a guard to cover the unused portion of the blade; 2. The , Ryobl 10 inch table saw, did not have a guard in place to cover the blade; 3. The Hitachi chop saw, model C12RSH, did not have a guard in place to cover the blade; 4. The Metal Muncher press, model MM35A, serial no. 05199593, did not have a guard at the point of operation; 5. The Central Machinery 16 speed drill press did not have a guard at the point of operation
Recent events (1)
- — Z (S) $2800
1910.212 A05
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a) On or about June 16, 2016, and at times prior, employees were exposed to injury where the rear blades of a fan on the floor near the welding area did not have guards. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1600
1910.219 D01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about June 16, 2016, and at times prior, employees were exposed to amputation hazards where the pulley on the rear of the fan located on the floor near the welding area was not guarded. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.219 E03 I
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) On or about June 16, 2016, and at times prior, employees were exposed to amputation hazards where the belt on the fan located on the floor near the welding area was not guarded. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.252 A02 II
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use: a) On or about June16, 2016, and at times prior, employees were exposed to fire and explosion hazards where, throughout the shop, fire extinguishers had not been maintained and/or inspected to ensure readiness in the event of an emergency.
Recent events (1)
- — Z (S) $1200
1910.253 B04 III
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half-hur: a) On or about June 16, 2016, and at times prior, employees where exposed to fire and explosion hazards where oxygen cylinders were stored immediately adjacent to acetylene and propane cylinders.
Recent events (1)
- — Z (S) $1200
1910.303 B02
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about June 16, 2016, and at times prior, employees were exposed to electrical hazards where a power strip used to supply power to the Central Machinery drill press was connected to the receptacle with an extension cord.
Recent events (1)
- — Z (S) $1200
1910.334 A01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: a) On or about June 16, 2016, and at times prior, employees were exposed to electrical hazards where extension cords throughout the shop were hung along walls and other metal surfaces which could damage the cords.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) On or about June 16, 2016, and at times prior, employees were exposed to electrical hazards where the power cord to the Millermatic 350P MIG welder was damaged, exposing the conductors.
Recent events (1)
- — Z (S) $0
1910.303 G01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about June 16, 2016, and at times prior, employees were exposed to electrical hazards where in the northeast corner of the shop, a minimum clearance of three feet was not maintained in front of the main electrical panel.
Recent events (1)
- — Z (O) $0
More inspections at Valiern Company
View Valiern Company's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341554061.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.