Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VALMIERA GLASS USA CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VALMIERA GLASS USA CORP. in 168 WILLIE PAULK PARKWAY, DUBLIN, GA 31021 (NAICS 327993). OSHA activity number 341556264.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valmiera Glass USA Corp. — free Get an email when a new federal OSHA severe-injury report for Valmiera Glass USA Corp. is published. One employer, no account, unsubscribe in one click.
Site address
168 WILLIE PAULK PARKWAY
City
DUBLIN
State
GA
ZIP
31021
Mailing
168 WILLIE PAULK PARKWAY, DUBLIN, GA 31021
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327993
Employees
48
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 9, 2016
Abate by
Dec 7, 2016
Penalty
Initial $6,236 · Current $6,236
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a). Non-Woven Line - On or about and times prior to June 14, 2016, there was no guarding between the end roller and its structural frame, thus exposing employees to an ingoing nip point hazard.
Recent events (1)
  • — Z (S) $6236

1910.147 C04 II

Repeat Gravity 10 1 instance 26 exposed
Issued
Nov 9, 2016
Abate by
Dec 7, 2016
Penalty
Initial $17,459 · Current $17,459
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section.  a). Production Area - On or about and times prior to June 14, 2016, the employer's written energy control procedure used during servicing and maintenance on the Blending and Non-Woven Line machinery did not specifically outline the following:  1. Specific statement for the intended use of the procedure  2. Steps for shutting down, isolating, blocking, and securing all sources of hazardous energy (e.g. electrical, pneumatic, hydraulic, gravity)  3. Steps for placement, removal, and transfer of lockout/tagout devices and the responsibility for them  4. Steps for testing machinery to verify effectiveness of lockout/tagout devices and other control measures.   5. Types of lockout/tagout devices to be utilized on isolation sources  Valmiera Glass USA Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(1), which was contained in OSHA inspection number 1101474, citation number 1, item number 1 and was affirmed as a final order on March 17, 2016, with respect to a workplace located at 168 Willie Paulk Parkway, Dublin, GA 31021.
Recent events (1)
  • — Z (R) $17459

1910.147 D03

Repeat Gravity 10 1 instance 26 exposed
Issued
Nov 9, 2016
Abate by
Dec 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).  a). Production Area - On or about and times prior to June 14, 2016, the energy isolating devices used to control the electrical source of energy to the Blending and Non-Woven Line machinery was not utilized, thus exposing employees to amputation injuries.  Valmiera Glass USA Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(1), which was contained in OSHA inspection number 1101474, citation number 1, item number 1 and was affirmed as a final order on March 17, 2016, with respect to a workplace located at 168 Willie Paulk Parkway, Dublin, GA 31021.
Recent events (1)
  • — Z (R) $0

1910.147 D04 I

Repeat Gravity 10 1 instance 26 exposed
Issued
Nov 9, 2016
Abate by
Dec 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.  a). Production Area - On or about and times prior to June 14, 2016, lockout/tagout devices were not affixed to energy isolating devices (e.g. pneumatic valves, electrical isolating device) during servicing and maintenance on the Blending and Non-Woven Line machinery, thus exposing employees to amputation injuries.  Valmiera Glass USA Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(1), which was contained in OSHA inspection number 1101474, citation number 1, item number 1 and was affirmed as a final order on March 17, 2016, with respect to a workplace located at 168 Willie Paulk Parkway, Dublin, GA 31021.
Recent events (1)
  • — Z (R) $0

1910.1200 E01

Repeat 1 instance 3 exposed
Issued
Nov 9, 2016
Abate by
Dec 7, 2016
Penalty
Initial $249 · Current $249
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  a). Production Area - On or about and times prior to June 14, 2016, the employer did not develop and implement a written hazard communication for employees that used hazardous chemicals such as, but not limited to oils, lubricant greases, and cleaners, thus exposing employees to chemical hazards.  Valmiera Glass USA Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(e)(1), which was contained in OSHA inspection number 1101474, citation number 1, item number 3a and was affirmed as a final order on March 17, 2016, with respect to a workplace located at 168 Willie Paulk Parkway, Dublin, GA 31021.
Recent events (1)
  • — Z (R) $249

View Valmiera Glass USA Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341556264.