Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FISCHER-ULMAN CONSTRUCTION, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FISCHER-ULMAN CONSTRUCTION, INC. in LAWERANCE & SUPERIOR RED RAMP, APPLETON, WI 54915 (NAICS 238140). OSHA activity number 341563484.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fischer-Ulman Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Fischer-Ulman Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
LAWERANCE & SUPERIOR RED RAMP
City
APPLETON
State
WI
ZIP
54915
Mailing
915 S. MIDPARK DR., APPLETON, WI 54914
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 29, 2016
Abate by
Oct 17, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced

Hazardous substances 9010

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103)    a.  Fischer-Ulman Construction, Inc. project site located at the Lawrence & Superior Red Ramp Appleton, WI 54915:  On or about June 21, 2016, Fischer-Ulman Construction, Inc. did not have a written respiratory protection program that included provisions in 29CFR 1910.134(c)(1)(I) - (ix) with worksite specific procedures.    All provisions of 29CFR 1910.134(c) through (o) must be covered in a respiratory protection program.  Key elements include but are not limited to the following:        1.  Evaluation of respiratory hazards in the workplace.      2.  Medical evaluations of employees.      3.  Fit testing.      4.  Training and information.      5.  Recordkeeping.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.134 D01 III

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 29, 2016
Abate by
Oct 17, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103)    a.  Fischer-Ulman Construction, Inc. project site located at the Lawrence & Superior Red Ramp Appleton, WI 54915:  On or about June 21, 2016, Fischer-Ulman Construction, Inc. did not identify and estimate the exposure to respiratory hazards employees might be exposed to while dry cutting concrete and sweeping the dust produced during repairs to a parking ramp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 29, 2016
Abate by
Oct 17, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)    a.  On or about June 21, 2016, Fischer-Ulman Construction, Inc. did not provide employees medical evaluations prior to requiring them to wear a respirator when dry cutting concrete or sweeping the dust produced during repairs to a parking ramp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 29, 2016
Abate by
Oct 17, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103)    a.  On or about June 21, 2016, Fischer-Ulman Construction, Inc. did not ensure that employees passed the appropriate qualitative or quantitative fit test prior to requiring them to use tight-fitting respirators while dry cutting concrete and sweeping the dust produced during repairs to a parking ramp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 29, 2016
Abate by
Oct 17, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  (Construction Reference 1926.103)    a.   On or about June 21, 2016, Fischer-Ulman Construction, Inc. did not provide training on the limits and use of respirators prior to requiring employees to wear respirators in the workplace while dry cutting concrete and sweeping the dust produced during repairs to a parking ramp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Fischer-Ulman Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341563484.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.