Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: ALL STAR ENERGY INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ALL STAR ENERGY INC. in 3800 SCOTTSVILLE ROAD, SCOTTSVILLE, NY 14546 (NAICS 238310). OSHA activity number 341565786.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Star Energy INC. for free Get an email when a new federal OSHA severe-injury report for ALL Star Energy INC. is published. One employer, no account, unsubscribe in one click.
Site address
3800 SCOTTSVILLE ROAD
City
SCOTTSVILLE
State
NY
ZIP
14546
Mailing
3800 SCOTTSVILLE ROAD, SCOTTSVILLE, NY 14546
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.134 C02

Serious Gravity 5 8 instances 8 exposed
Issued
Dec 1, 2016
Abate by
Jan 3, 2017
Penalty
Initial $4,988 · Current $4,000 Reduced
29 CFR 1910.134(c)(2): The employer did not develop and implement a respiratory protection program in accordance with sections i and ii of this paragraph (c)(2) for employees who chose to wear respirators where respirator use was not required:    (a) On or about 7/6/16, eight weatherization employees wear 3M elastomeric full face or half face respirators.  The employer has not ensured that employees were medically able to wear a respirator.     ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • · J (S) $4000
  • · C (S) $4988
  • · Z (S) $4988

1910.305 B02 I

Other-than-serious 1 instance 4 exposed
Issued
Dec 1, 2016
Penalty
Initial $4,988 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) Warehouse - On or about 6/21/16, a dual outlet electrical box with a light switch lacked a cover.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • · J (O) $0
  • · C (S) $4988
  • · Z (S) $4988

1926.1101 K09 VI

Other-than-serious 16 instances 8 exposed
Issued
Dec 1, 2016
Abate by
Jan 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(k)(9)(vi): Training for employees performing Class IV operations did not include available information concerning the locations of thermal system insulation and surfacing asbestos containing material and/or presumed asbestos containing material, asbestos-containing flooring materials, or flooring material where the absence of asbestos has not yet been certified; and instruction in recognition of damage, deterioration, and delamination of asbestos containing building materials; and did not take at least 2 hours:   a) On or about 6/21/16, energy auditor and insulator employees conduct energy audits or spray foam insulation into residential houses.  These employees have potential exposure to airborne asbestos fibers present in house insulation and have not received appropriate asbestos training.  ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • · J (O) $0
  • · C (O) $0
  • · Z (O) $0

View ALL Star Energy INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341565786.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.