Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAR-LEE COMPANIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAR-LEE COMPANIES, INC. in 180 AUHTORITY DRIVE, FITCHBURG, MA 01420 (NAICS 326160). OSHA activity number 341567345.

Watch Mar-Lee Companies, INC. — free Get an email when a new federal OSHA severe-injury report for Mar-Lee Companies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
180 AUHTORITY DRIVE
City
FITCHBURG
State
MA
ZIP
01420
Mailing
190 AUTHORITY DRIVE, FITCHBURG, MA 01420
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
84
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3500.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    180 Authority Drive, Fitchburg, MA: On or about June 20, 2016 the employer had not developed or utilized a procedure for the control of potentially hazardous energy for the Engel e-motion 550 injection molder to ensure employees were protected from the unintended energization during repair and maintenance activities covered by this section.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4900

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3500.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    180 Authority Drive, Fitchburg, MA: On or about June 21, 2016 employer had not conducted periodic inspections of the energy control procedures for the years 2015 and 2016 to ensure that the procedure and the requirements of this standard were followed.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4900

1910.147 C06 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  180 Authority Drive, Fitchburg, MA: On or about June 21, 2016 employer had not certified that a periodic inspection of the energy control plan had been conducted for 2015 and 2016.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341567345.