FITCHBURG, MA ·
OSHA Inspection: MAR-LEE COMPANIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAR-LEE COMPANIES, INC. in 180 AUHTORITY DRIVE, FITCHBURG, MA 01420 (NAICS 326160). OSHA activity number 341567345.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAR-LEE COMPANIES, INC.
- Site address
- 180 AUHTORITY DRIVE
- City
- FITCHBURG
- State
- MA
- ZIP
- 01420
- Mailing
- 190 AUTHORITY DRIVE, FITCHBURG, MA 01420
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- Employees
- 84
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $4,900 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 180 Authority Drive, Fitchburg, MA: On or about June 20, 2016 the employer had not developed or utilized a procedure for the control of potentially hazardous energy for the Engel e-motion 550 injection molder to ensure employees were protected from the unintended energization during repair and maintenance activities covered by this section. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $3500
- · Z (S) $4900
1910.147 C06 I
- Issued
- Jul 29, 2016
- Abate by
- Sep 15, 2016
- Penalty
- Initial $4,900 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: 180 Authority Drive, Fitchburg, MA: On or about June 21, 2016 employer had not conducted periodic inspections of the energy control procedures for the years 2015 and 2016 to ensure that the procedure and the requirements of this standard were followed. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $3500
- · Z (S) $4900
1910.147 C06 II
- Issued
- Jul 29, 2016
- Abate by
- Sep 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: 180 Authority Drive, Fitchburg, MA: On or about June 21, 2016 employer had not certified that a periodic inspection of the energy control plan had been conducted for 2015 and 2016. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $0
- · Z (S) $0