OSHA Inspection: KNAUF INSULATION, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KNAUF INSULATION, INC in 3502 43RD STREET SW, LANETT, AL 36863 (NAICS 327211). OSHA activity number 341567709.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Knauf Insulation, INC for free Get an email when a new federal OSHA severe-injury report for Knauf Insulation, INC is published. One employer, no account, unsubscribe in one click.
Site address
3502 43RD STREET SW
City
LANETT
State
AL
ZIP
36863
Mailing
3502 43RD STREET SW, LANETT, AL 36863
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327211
Employees
250
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 B01

Serious Gravity 10 2 instances 11 exposed
Issued
Sep 14, 2016
Abate by
Oct 3, 2016
Penalty
Initial $12,471 · Current $8,144 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.  a)  Throughout  Warehouse 1; on or about June 15, 2016 and at times prior thereto the employer exposed employees to struck-by, slip/trip, and entrapment hazards in that employees were allowed to walk and work around aisles and passages that were not maintained in a clean and unobstructed condition.  b)   Thoughout Warehouse 2; on or about June 15, 2016 and at times prior thereto the employer exposed employees to struck-by, slip/trip, and entrapment hazards in that employees were allowed to walk and work around aisles and passages that were not maintained in a clean and unobstructed condition.
Recent events (2)
  • · I (S) $8144
  • · Z (S) $12471

1910.37 A03

Serious Gravity 10 7 instances 10 exposed
Issued
Sep 14, 2016
Abate by
Sep 26, 2016
Penalty
Initial $12,471 · Current $8,142 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a)  Warehouse 1 front wall; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of the exit door.  b)  Warehouse 1 front wall rear of the building; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of the exit door.  c)  Warehouse 1 loading dock: On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing a metal bar to be stored in front of the exit door.  d)  Warehouse 1 loading dock side in rear of building; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of exit doors.  e)  Warehouse 1 middle of the rear wall; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of exit doors.  f)  Warehouse 2 loading dock side; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of exit doors.  g)  Warehouse 2 loading back side; On or about June 15, 2016 and at times prior thereto the employer exposed employees to slip/trip and entrapment hazards in that exit routes were not maintained in a condition free of obstructions due to the employer allowing material to be stored in front of exit doors.
Recent events (2)
  • · I (S) $8142
  • · Z (S) $12471

1910.176 B

Serious Gravity 10 2 instances 11 exposed
Issued
Sep 14, 2016
Abate by
Oct 3, 2016
Penalty
Initial $12,471 · Current $8,142 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  a)  Throughout Warehouse 1; on or about June 15, 2016 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to walk and work around improperly stacked insulation rolls and bags weighting up to 200 lbs that were damaged and routinely collapsed.  b)  Throughout Warehouse 2; on or about June 15, 2016 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to walk and work around improperly stacked insulation rolls and bags weighting up to 200 lbs that were damaged and routinely collapsed.
Recent events (2)
  • · I (S) $8142
  • · Z (S) $12471

1910.303 G01 I C

Other-than-serious 4 instances 2 exposed
Issued
Sep 14, 2016
Abate by
Sep 26, 2016
Penalty
Initial $7,572 · Current $7,572
29 CFR 1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303:    a)  Warehouse 1 front wall; On or about June 15, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that clear access was not maintained in front of a 208 volt breaker panel.    b)  Warehouse 1 front wall; On or about June 15, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that clear access was not maintained in front of a 480 volt breaker panel.    c)  Warehouse 1loading dock bay 10; On or about June 15, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that clear access was not maintained in front of a 480 volt breaker panel.    d)  Warehouse 1 loading dock bay 10; On or about June 15, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that clear access was not maintained in front of a 480 volt electrical disconnect.
Recent events (2)
  • · I (O) $7572
  • · Z (S) $7572

View Knauf Insulation, INC's full OSHA safety record →