Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENTURY READY MIX

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CENTURY READY MIX in 101 S MAPLE STREET, RUSTON, LA 71270 (NAICS 327320). OSHA activity number 341568145.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Century Ready MIX — free Get an email when a new federal OSHA severe-injury report for Century Ready MIX is published. One employer, no account, unsubscribe in one click.
Establishment
CENTURY READY MIX
Site address
101 S MAPLE STREET
City
RUSTON
State
LA
ZIP
71270
Mailing
3250 ARMAND ST., MONROE, LA 71203
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
10
Ownership type
A

8 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 5 instances 3 exposed
Issued
Jul 25, 2016
Abate by
Aug 7, 2016
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:  a) On or about 6/22/2016, on the fly ash silo ladderway, the employer allowed employees to service a dust collector on top of the fly ash silo and did not ensure that a swinging gate was provided for the passage through the railing.   b) On or about 6/22/2016, on the ladderway platform on the central cement silo, the employer allowed employees to access the platform in order to conduct maintenance and did not ensure that a swinging gate was provided for the passage through the railing.   c) On or about 6/22/2016, on the ladderway leading to the top of the central cement silo, the employer allowed employees to access the platform on top of the silo in order to service a dust collector and did not ensure that a swinging gate was provided for the passage through the railing.  d) On or about 6/22/2016, on the ladderway on the north cement silo, the employer allowed employees to conduct maintenance and did not ensure that a swinging gate was provided for the passage through the railing.  e) On or about 6/22/2016, on the ladderway platform between the hopper and the fly ash silo, the employer did not ensure that standard railings and a swinging gate were provided.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.23 C01

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 25, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  a) On or about 6/22/2016, on the platform under the north side cement silo, the employer allowed employees to conduct maintenance and did not ensure that standard railings were provided.   b) On or about 6/22/2016, on the work platform between the hopper and the fly ash silo, the employer allowed employees to conduct maintenance and did not ensure that standard railings were provided.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.151 C

Serious Gravity 5 1 instance 7 exposed
Issued
Jul 25, 2016
Abate by
Aug 7, 2016
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about 6/23/2016, on the south side of the garage, the employer allowed employees to use a corrosive concrete removal solution (Kwik Sand Ultra) and did not provide an eyewash station or shower.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 25, 2016
Abate by
Aug 11, 2016
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  On or about 6/22/2016, in the southeast corner of the garage, the employer allowed employees to conduct vehicle maintenance near an area where compressed oxygen was stored next to cylinders of dissolved acetylene.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.1200 G08

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 25, 2016
Abate by
Aug 7, 2016
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.1200(g)(8):   The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s):   On or about 6/22/2016, at 101 South Maple Street in Ruston, LA, the employer did not ensure that Safety Data Sheets were readily available.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.27 D01 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2016
Abate by
Aug 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.27(d)(1)(ii): Cages or wells shall be provided for fixed ladders of more than 20 feet (except as provided in subparagraph 5 of this paragraph) to a maximum unbroken length of 30 feet:  On or about 6/22/2016, on the east side of the central cement silo, the employer did not provide a cage for a ladder with unbroken length greater than 20 feet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.219 D01

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2016
Abate by
Aug 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  On or about 6/22/2016, on the platform under the north cement silo, the employer allowed employees to conduct maintenance did not ensure that pulleys were guarded.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.219 E03 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2016
Abate by
Aug 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  On or about 6/22/2016, on the platform under the north cement silo, the employer allowed employees to conduct maintenance and did not ensure that belts were guarded against accidental contact.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Century Ready MIX's full OSHA safety record →