Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUOR FACILITY & PLANT SERVICES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLUOR FACILITY & PLANT SERVICES in 6300 DIAGONAL HIGHWAY, BOULDER, CO 80301 (NAICS 541513). OSHA activity number 341572337.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluor Facility & Plant Services — free Get an email when a new federal OSHA severe-injury report for Fluor Facility & Plant Services is published. One employer, no account, unsubscribe in one click.
Site address
6300 DIAGONAL HIGHWAY
City
BOULDER
State
CO
ZIP
80301
Mailing
6300 DIAGONAL HIGHWAY, BOULDER, CO 80301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541513
Employees
50000
Ownership type
A

2 citations on file for this inspection.

1910.132 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2016
Abate by
Dec 22, 2016
Penalty
Initial $6,057 · Current $0 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  (a) Fluor Facility & Plant Services at 6300 Diagonal Hwy, Boulder, CO 80301: On and before July 13, 2016, the employer did not ensure that the workplace was assessed to determine if hazards were present which would necessitate the use of personal protective equipment. The employer did not ensure that employees performing maintenance activities to replace a valve on a steam boiler system were provided with and used hard hats. This condition exposed employees to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6057

1910.135 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2016
Abate by
Dec 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:  (a) Fluor Facility & Plant Services at 6300 Diagonal Hwy, Boulder, CO 80301: On and before July 13, 2016, the employer did not ensure that employees performing maintenance activities to replace a valve on a steam boiler system were provided with and used hard hats. This condition exposed employees to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341572337.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.