Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VEKA INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VEKA INCORPORATED in 100 VEKA DRIVE, FOMBELL, PA 16123 (NAICS 326199). OSHA activity number 341573947.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veka Incorporated for free Get an email when a new federal OSHA severe-injury report for Veka Incorporated is published. One employer, no account, unsubscribe in one click.
Establishment
VEKA INCORPORATED
Site address
100 VEKA DRIVE
City
FOMBELL
State
PA
ZIP
16123
Mailing
100 VEKA DRIVE, FOMBELL, PA 16123
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
475
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 25, 2016
Abate by
Aug 4, 2016
Penalty
Initial $7,000 · Current $6,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     (a) Facility:  On or about June 21, 2016, the employer did not developed, documented and utilized procedures for the control of potentially hazardous energy sources for the Line 56 embosser.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $7000

1910.147 C08

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance:   (a)  Facility:  On or about June 21, 2016, the Line 56 embossing machine was not properly locked out nor tagged out in that the machine was never unplugged.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 E02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jul 25, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(e)(2):  Before lockout/tagout devices are removed and energy is restored to the machine the work area was not checked to ensure that all employees had been safely positioned or removed:  (a)  Facility:  On or about June 21, 2016, an employee was not safely positioned while another employee turned on the line 56 embossing machine and activated a part of the machine causing an injury to the first employee.  The two employees were doing maintenance on the line 56 embossing machine.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.303 F04

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2016
Penalty
Initial $3,400 · Current $3,000 Reduced
29 CFR 1910.303(f)(4): Disconnecting means were not capable of accepting a lock in the open position:    (a) Facility:  On or about June 21, 2016 , the electrical disconnecting means to the electrical panel located on the Line 56 embosser was broken and could not be locked out.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3400

1910.305 G01 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(ii): Flexible cords may only be used for sections (A) through (L) of this section:  (a) Facility:  On or about June 21, 2016, the 480 vAC Line 56 embosser was fitted with an electrical cord and plug.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   (a) Facility:  On or about June 21, 2016, an employees was exposed to 480 vAC while he was working inside the electrical panel to the Line 56 embossing machine.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341573947.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.