SHERMAN, TX ·
OSHA Inspection: KAISER ALUMINUM & FABRICATED PRODUCTS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KAISER ALUMINUM & FABRICATED PRODUCTS, LLC in 4300 HIGHWAY 75 SOUTH, SHERMAN, TX 75090 (NAICS 331316). OSHA activity number 341574366.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KAISER ALUMINUM & FABRICATED PRODUCTS, LLC
- Site address
- 4300 HIGHWAY 75 SOUTH
- City
- SHERMAN
- State
- TX
- ZIP
- 75090
- Mailing
- 4300 HIGHWAY 75 SOUTH, SHERMAN, TX 75090
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331316
- Employees
- 175
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $7,126 · Current $6,499 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. In the extrusion plant, the employer did not ensure that the 2750 Extrusion Press Hydraulic Mezzanine platform and stairs were maintained in a clean condition exposing employees to slip and fall hazards.
Recent events (3)
- · J (O) $6499
- · C (S) $7126
- · Z (S) $7126
1910.147 C07
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $12,471 · Current $11,508 Reduced
General-duty citation text
29 CFR 1910.147(c)(7): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: In the plant extrusion building, the employer did not develop or implement written lockout/tag-out procedures for each type of equipment or machine. Employees performed maintenance on machines and equipment including, but not limited to the 2750T Press and billet loader exposing the employees to crushed-by and amputation hazards.
Recent events (3)
- · J (S) $11508
- · C (S) $12471
- · Z (S) $12471
1910.147 C06 I
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $8,908 · Current $7,747 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. In the plant extrusion building, the employer did not ensure energy control procedures were reviewed annually exposing employees to electrical, amputation, struck-by and crush-by hazards. 1. LO# 2750-001 2. LO# 2750-004 3. LO# 2750-005 4. LO# 2750-006 5. LO# 2750-007 6. LO#2750-008 7. LO#2750-010 8. LO# 2750-011 9. LO# 2750-012 10. LO#2750-013 11. LO# 2750-014 12. LO# 2750-015 13. LO# 2750-016 14. LO# 2750-017 15. LO# 2750-018 16. LO#2750-019 17. LO# 2750-020 18. LO# 2750-021 19. LO# 2750-022 20. LO# 2750-023 21. LO# 2750-024 22. LO# 2750-025
Recent events (3)
- · J (O) $7747
- · C (S) $8908
- · Z (S) $8908
1910.147 D04 I
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: In the plant extrusion building, the employer did not ensure that lockout/tagout devices were applied or used on the 2750T Press billet loader at the time of making repairs to the cam-pusher knob photo sensor exposing the employee to amputation hazards.
Recent events (3)
- · J (S) $0
- · C (S) $12471
- · Z (S) $12471
1910.212 A03 II
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): In the plant extrusion building, the employer did not ensure that the extrusion presses points of operation were guarded exposing the employees to crushed-by and amputation hazards. 1. INNSE 2750 2. Ube 3600 3. Farrell 1650
Recent events (3)
- · J (S) $0
- · C (S) $12471
- · Z (S) $12471
1910.217 C02 I A
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $7,126 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): In the KFAB production building, the employer did not ensure the point of operation guarding for revolution mechanical power presses were securely fastened. Employees were exposed to crush-by and amputation hazards. 1. WARCO 100-2-84CG 100 Ton Stamping Press 2. HEIM 7GA-FLYWHL 70 Ton Stamping Press 3. SEYI Mark 50 50 Ton Stamping Press
Recent events (3)
- · J (S) $0
- · C (S) $7126
- · Z (S) $7126
1910.303 B02
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $7,126 · Current $6,499 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listed or labeling: In the plant extrusion building, employees adjoined two (2) plug electrical receptacle boxes wired with a flexible cord to supply electrical power to the 1650 Press Stencilers. The shop made receptacles were not used in accordance with any instructions included in the listing and labeling.
Recent events (3)
- · J (O) $6499
- · C (S) $7126
- · Z (S) $7126
1910.305 G02 III
- Issued
- Dec 7, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $8,908 · Current $7,747 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: In the extrusion plant, the employer did not ensure that the 3600 Extrusion Press Patterson Swirl Cage fan flexible cord was provided with strain relief exposing the employees to electrical shock hazards.
Recent events (3)
- · J (O) $7747
- · C (S) $8908
- · Z (S) $8908
More inspections at Kaiser Aluminum & Fabricated Products, LLC
View Kaiser Aluminum & Fabricated Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331316)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341574366.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.