KENNER, LA —
OSHA Inspection: PELLERIN MILNOR CORPORATION, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PELLERIN MILNOR CORPORATION, INC. in 700 JACKSON ST, KENNER, LA 70062 (NAICS 333312). OSHA activity number 341581437.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PELLERIN MILNOR CORPORATION, INC.
- Site address
- 700 JACKSON ST
- City
- KENNER
- State
- LA
- ZIP
- 70062
- Mailing
- 700 JACKSON ST, KENNER, LA 70062
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333312
- Employees
- 550
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Dec 15, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. On or about June 23, 2016 on the north side of the shop, the service procedures for equipment such as, but not limited to, the MacTurn 550W CNC Lathe failed to clearly identify all of the specific steps to be followed by employees to de-energize the equipment and control the hazardous energy. Employees were thereby exposed to the unexpected re-energization of equipment.
Recent events (2)
- — I (S) $12471
- — Z (S) $12471
1910.147 C07 I
- Issued
- Dec 15, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about June 24, 2016 throughout the facility, the employer allowed employees to operate a MacTurn 550W CNC Lathe without ensuring that the employees were trained on an energy control program applicable to the equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $12471
1910.147 C06 I
- Issued
- Dec 15, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $8,908 · Current $8,908
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On or about June 24, 2016 throughout the facility, the employer had not performed annual periodic inspections of the energy control procedures.
Recent events (2)
- — I (S) $8908
- — Z (S) $8908
1910.147 D04 II
- Issued
- Dec 15, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position: On or about June 23, 2016 on the north side of the shop, the employer did not ensure that lockout devices were used to isolate all energy sources, thereby exposing employees to potential re-energization of equipment. Employees were allowed to use an e-stop to control/deenergize equipment while entering the equipment to perform inspections of the part.
Recent events (2)
- — I (S) $0
- — Z (S) $12471
1910.243 C03
- Issued
- Dec 15, 2016
- Abate by
- Dec 30, 2016
- Penalty
- Initial $8,908 · Current $8,908
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel. On or about June 28, 2016 on the north side of the facility, the employer allowed employee to use a top cat air tool without a guard, to grind on tunnel sheet metal. Employee was thereby exposed to a struck-by hazard.
Recent events (2)
- — I (S) $8908
- — Z (S) $8908
More inspections at Pellerin Milnor Corporation, INC.
View Pellerin Milnor Corporation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333312)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341581437.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.