Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PANTANO AND SONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PANTANO AND SONS, INC. in 121 S BROAD STREET, PHILADELPHIA, PA 19107 (NAICS 238910). OSHA activity number 341589059.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pantano and Sons, INC. for free Get an email when a new federal OSHA severe-injury report for Pantano and Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
121 S BROAD STREET
City
PHILADELPHIA
State
PA
ZIP
19107
Mailing
316 W POPLAR STREET, NORRISTOWN, PA 19401
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
20
Ownership type
Private (A)

3 citations on file for this inspection.

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 16, 2016
Abate by
Dec 22, 2016
Penalty
Initial $4,988 · Current $3,741 Reduced
29 CFR 1926.416(a)(3): When and where energized circuits existed, the employer failed to post and maintain proper warning signs, advise employees of the location, hazard involved, and the proper protective measures to be taken:    a) Jobsite: Hip City Veg space, mezzanine - Employees conducting demolition of electrical wires were exposed to shock hazards as the employer did not post and maintain proper warning signs, or advise employees of the location of the energized wires, the hazards involved, and the protective measures to be taken.  An employee who cut an unidentified energized electrical wire with a wire cutter was shocked and hospitalized.    Noted on or about 6/16/16.
Recent events (2)
  • · I (S) $3741
  • · Z (S) $4988

1926.850 D

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 16, 2016
Abate by
Dec 22, 2016
Penalty
Initial $4,988 · Current $0 Reduced
29 CFR 1926.850(d): Electrical power, water or other utility lines required to remain available during demolition were not temporarily relocated and protected, as necessary.    a) Jobsite: Hip City Veg space, mezzanine -  Employees conducting demolition of electrical wires were exposed to shock hazards as the employer did not temporarily relocate or protect the temporary power line needed to power their equipment.      Noted on or about 6/16/16.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4988

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 16, 2016
Abate by
Dec 22, 2016
Penalty
Initial $4,988 · Current $3,741 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, safety net system, or personal fall arrest system.    a) Jobsite: Hip City Veg space - An employee conducting demolition activities on the concrete mezzanine, 8 feet above ground level, was exposed to fall hazards without the use of a fall protection system.    Noted on or about 6/16/16.