CONROE, TX —
OSHA Inspection: AWC FRAC VALVES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AWC FRAC VALVES, INC. in 11376 FM 2854 RD, CONROE, TX 77304 (NAICS 332919). OSHA activity number 341590024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AWC FRAC VALVES, INC.
- Site address
- 11376 FM 2854 RD
- City
- CONROE
- State
- TX
- ZIP
- 77304
- Mailing
- 11376 FM 2854 RD, CONROE, TX 77304
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332919
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 22, 2016
- Abate by
- Jul 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD) Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. On or about June 24, 2016, on the NDE-QC Dept., employees were allowed to wear 3M half-face respirators without a medical evaluation to determine the employee's ability to use a respirator.
Recent events (1)
- — Z (O) $0
1910.134 F01
- Issued
- Jul 22, 2016
- Abate by
- Jul 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about June 24, 2016, in the NDE-QC Dept., employees were allowed to wear 3M half-face respirators without being fit tested.
Recent events (1)
- — Z (O) $0
More inspections at AWC Frac Valves, INC.
View AWC Frac Valves, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332919)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341590024.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.