Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GATEWAY ACQUISITIONS, INC. DBA GATEWAY MOTORSPORTS PARK

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GATEWAY ACQUISITIONS, INC. DBA GATEWAY MOTORSPORTS PARK in 700 RACEWAY DRIVE, MADISON, IL 62060 (NAICS 711212). OSHA activity number 341594893.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gateway Acquisitions, INC. DBA Gateway Motorsports Park for free Get an email when a new federal OSHA severe-injury report for Gateway Acquisitions, INC. DBA Gateway Motorsports Park is published. One employer, no account, unsubscribe in one click.
Site address
700 RACEWAY DRIVE
City
MADISON
State
IL
ZIP
62060
Mailing
700 RACEWAY DRIVE, MADISON, IL 62060
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
711212
Employees
115
Ownership type
Private (A)

7 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 31, 2017
Penalty
Initial $11,224 · Current $5,612 Reduced
29 CFR 1910.106(e)(2)(iv)(d):  Flammable liquids shall be drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve. Transferring by means of air pressure on the container or portable tanks shall be prohibited.    At the drag strip, in the track adhesive mixing container, employees were exposed to explosion hazards when Category 2 flammable liquids were transferred into a fifty-five (55) gallon drum by use of pneumatic pressure.
Recent events (2)
  • · I (S) $5612
  • · Z (S) $11224

1910.106 E03 IV A

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 31, 2017
Penalty
Initial $8,017 · Current $4,009 Reduced
29 CFR 1910.106(e)(3)(iv)(a): Emergency drainage systems shall be provided to direct flammable liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire; see paragraph (b)(2)(vii)(b) of this section:    At the drag strip, in the track adhesive storage and mixing containers, employees were exposed to explosion hazards when emergency drainage systems were not provided for Category 2 flammable liquids that was being stored and transferred between containers.
Recent events (2)
  • · I (S) $4008.5
  • · Z (S) $8017

1910.106 E06 I

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 18, 2017
Penalty
Initial $11,224 · Current $5,612 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:    At the drag strip, in the track adhesive mixing container, employees were exposed to explosion hazards when Category 2 flammable liquids were transferred by use of a rubber hose, increasing the potential for static buildup.
Recent events (2)
  • · I (S) $5612
  • · Z (S) $11224

1910.106 E06 II

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii):  Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  At the drag strip, in the track adhesive mixing container, employees were exposed to explosion hazards when Category 2 flammable liquids were being dispensed into containers without the nozzle and/or containers being electrically interconnected, as required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C01

Other-than-serious 2 instances 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 18, 2017
Penalty
Initial $4,810 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    The employer did not ensure that fire extinguishers, located in the drag strip track adhesive production area, were mounted.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4810

1910.1200 G01

Other-than-serious 1 instance 5 exposed
Issued
Dec 12, 2016
Abate by
Jan 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers did not obtain or develop a safety data sheet for each hazardous chemical and for each chemical that posed a hazard not otherwise classified that they produce or import  The employer did not ensure that Safety Data Sheets (SDS) were created when Category 2 Flammable products were mixed together to create hazardous chemicals, such as drag strip adhesive.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 5 exposed
Issued
Dec 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s)  The employer did not ensure that Safety Data Sheets were available to all employees who were exposed to hazardous chemicals including, but not limited to, VP Racing - Methylfuel M1 and VP Racing - Lane Choice 7 Track Adhesive.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341594893.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.