Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: V & V CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of V & V CONSTRUCTION, INC. in 9600 SUMMIT POINT DR., MIAMISBURG, OH 45342 (NAICS 238130). OSHA activity number 341595494.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V & V Construction, INC. — free Get an email when a new federal OSHA severe-injury report for V & V Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9600 SUMMIT POINT DR.
City
MIAMISBURG
State
OH
ZIP
45342
Mailing
5255 PIN OAK DR., INDIANAPOLIS, IN 46254
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 29, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    Located on the west side of a residential steep roof structure, employees were exposed to a fall hazard while performing framing work and providing hand signals to a crane operator while not utilizing any fall protection system. Potential fall height was measured to be greater than 25' with a roof pitch that measured to be 6 in 12.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.1428 A03

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 29, 2016
Abate by
Aug 17, 2016
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.1428(a)(3): The employer must make the documentation for whichever option is used available at the site while the signal person is employed by the employer. The documentation must specify each type of signaling (e.g. hand signals, radio signals, etc.) for which the signal person meets the requirements of paragraph (c) of this section.    Located on the west side of a residential steep roof structure, an employee was observed providing hand signals to a crane operator that did not have the required signal training documentation available on-site to verify qualifications of the specify type of signal training for which the signal person must meet.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

View V & V Construction, INC.'s full OSHA safety record →