BUFFALO, NY —
OSHA Inspection: TAMMY FISHER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TAMMY FISHER in 197 VIRGINIA STREET, BUFFALO, NY 14201 (NAICS 236118). OSHA activity number 341595809.
Where did this inspection happen?
- Establishment
- TAMMY FISHER
- Site address
- 197 VIRGINIA STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14201
- Mailing
- 8614 ROUTE 353, GOWANDA, NY 14070
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B03
- Issued
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation: a) On or about 07/01/16, on the second floor of an old building under renovation at 197 Virginia Street, Buffalo, NY: A Craftsman table saw that lacked a blade guard, had an unguarded drive belt & pulley, and was missing the ground prong on its plug, was not identified as unsafe by tagging or locking the controls to render them inoperable. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $1200
- — Z (S) $1200
1926.150 C01 I
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) On or about 07/01/16, in old building under renovation at 197 Virginia Street, Buffalo, NY: The building was 4 stories high plus a basement, (total sq.ft. not provided). No fire extinguishers were provided. At least one fire extinguisher must be adjacent to the stairway on each floor including the basement. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.501 B14
- Issued
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) On or about 07/01/16, in old building under renovation at 197 Virginia Street, Buffalo, NY: Employees were exposed to a potential fall ranging from approx. 15 to 30 ft. through window openings while working on the second, third, and fourth floors. The bottom edge of the window openings were typically 27 inches or less above the floor, and there were 4 such window openings on the second floor, 13 such window openings on the third floor, and 5 such window openings on the fourth floor. Each window opening lacked a top rail. No other fall protection system was used to protect employees from falling through the window openings. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $2800
- — Z (S) $2800
1926.1052 C01 II
- Issued
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) On or about 07/01/16, on the stairway from the fourth floor to the third floor of an old building under renovation at 197 Virginia Street, Buffalo, NY: Employee was exposed to a potential fall down/off the stairway which had approx. 12 risers and was not enclosed on the left side descending. No stair rail system (that includes an intermediate component, screen, or mesh) was present on this side. b) On or about 07/01/16, on the stairway from the third floor to the second floor of an old building under renovation at 197 Virginia Street, Buffalo, NY: Employee was exposed to a potential fall down/off the stairway which had approx. 12 risers and was not enclosed on the left side descending. No stair rail system (that includes an intermediate component, screen, or mesh) was present on this side. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $2400
- — Z (S) $2400
1926.1052 C12
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) On or about 07/01/16, on the fourth floor of an old building under renovation at 197 Virginia Street, Buffalo, NY: A guardrail system was installed along the north side and east end of a stairway opening to prevent employees from falling up to 10 ft. onto the stairs or floor below. The guardrail system was deficient in that the top rails were only 29.25 inches above the floor, and there were no midrails installed. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B04 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) On or about 07/01/16, in old building under renovation at 197 Virginia Street, Buffalo, NY: Employees were exposed to stepping into a floor hole (approx. 14 in. x 3 in.) along the south wall while working on the first floor, and into a floor hole (approx. 10 in. x 4 in.) near vertical posts on the third floor. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341595809.