MIDDLETON, WI —
OSHA Inspection: NATIONAL ELECTROSTATICS CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NATIONAL ELECTROSTATICS CORP. in 7540 GRABER ROAD P.O. BOX 620310, MIDDLETON, WI 53562 (NAICS 335999). OSHA activity number 341597169.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL ELECTROSTATICS CORP.
- Site address
- 7540 GRABER ROAD P.O. BOX 620310
- City
- MIDDLETON
- State
- WI
- ZIP
- 53562
- Mailing
- 7540 GRABER ROAD P.O. BOX 620310, MIDDLETON, WI 53562
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 91
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.141 A03 I
- Issued
- Nov 10, 2016
- Abate by
- Jan 31, 2017
- Penalty
- Initial $9,603 · Current $4,802 Reduced
0576
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: On or about July 5, 2016 there was cesium hydroxide compound on the working surface in the area where accelerators were manufactured.
Recent events (2)
- — I (O) $4802
- — Z (S) $9603
1910.1200 H03 III
- Issued
- Nov 10, 2016
- Abate by
- Jan 31, 2017
- Penalty
- Initial $9,603 · Current $4,801 Reduced
0576
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: On or about July 05, 2016 employees were not trained on a procedure to protect employees from cesium hydroxide exposure.
Recent events (2)
- — I (O) $4801
- — Z (S) $9603
More inspections at National Electrostatics Corp.
View National Electrostatics Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 335999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341597169.