Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: OFCO INC., A DELAWARE CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OFCO INC., A DELAWARE CORP. in 111 NORTH 14TH STREET, COSHOCTON, OH 43812 (NAICS 333999). OSHA activity number 341603371.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ofco INC., a Delaware Corp. for free Get an email when a new federal OSHA severe-injury report for Ofco INC., a Delaware Corp. is published. One employer, no account, unsubscribe in one click.
Site address
111 NORTH 14TH STREET
City
COSHOCTON
State
OH
ZIP
43812
Mailing
111 NORTH 14TH STREET, COSHOCTON, OH 43812
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
52
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 13, 2016
Abate by
Jan 17, 2017
Penalty
Initial $9,603 · Current $6,242 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:  a) At the workplace located at 111 North 14th Street, Coshocton, Ohio, specific energy control procedures for the Fab-Tube machine had not been developed and implemented to protect machine operators when clearing jams and performing machine adjustments. On or about July 6, 2016, a Fab-Tube machine operator suffered the amputation of three fingers while attempting to clear a jam and make machine adjustments in the mandrill area of the Fab-Tube machine.
Recent events (2)
  • · I (S) $6241.95
  • · Z (S) $9603

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 13, 2016
Abate by
Jan 17, 2017
Penalty
Initial $9,603 · Current $6,242 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a) On or about July 6, 2016 , the Fab-Tube operator suffered the amputation of three fingers while attempting to clear a jam in the mandrill area of the Fab-tube machine. The operator had not received training on the means to ensure that all power sources, to include but not limited to the air supply, had been isolated.
Recent events (2)
  • · I (S) $6241.95
  • · Z (S) $9603

1910.147 D02

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 13, 2016
Abate by
Jan 17, 2017
Penalty
Initial $9,603 · Current $6,242 Reduced
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.  a) On or about July 6, 2016, an employee suffered the amputation of three fingers while attempting to perform machine adjustments and clear a jam in the mandrill area of the Fab-Tube machine. The employer failed to implement energy isolating procedures to ensure that all energy sources had been shut down or turned off prior to performing servicing work.
Recent events (2)
  • · I (S) $6241.95
  • · Z (S) $9603

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 13, 2016
Abate by
Jan 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).  a) On or about July 6, 2016, an employee suffered the amputation of three fingers while attempting to clear a jam and perform machine adjustments in the mandrill area of the Fab-Tube machine. The employer failed to implement procedures to ensure that energy isolating devices were located in such a way as to ensure that all energy was isolated prior to breaching the Fab-Tube's barrier guard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 13, 2016
Abate by
Jan 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.   a) On or about July 6, 2016, an employee suffered the amputation of three fingers while attempting to clear a jam and perform machine adjustments in the mandrill area of the Fab-Tube machine. The employer failed to implement energy control procedures to ensure that all energy sources to the Fab-Tube machine had been isolated and lock-out devices installed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D06

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 13, 2016
Abate by
Oct 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.  a) On or about July 6, 2016, an employee suffered the amputation of three fingers while attempting to clear a jam and perform machine adjustments in the mandrill area of the Fab-Tube machine. The employer failed to implement procedures that would ensure that steps were taken to verify that all energy sources had been isolated and deenergized prior to any work.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Ofco INC., a Delaware Corp.'s full OSHA safety record →