PARAGOULD, AR ·
OSHA Inspection: TENNECO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TENNECO, INC. in 1601 HIGHWAY 49B NORTH, PARAGOULD, AR 72450 (NAICS 336330). OSHA activity number 341604890.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TENNECO, INC.
- Site address
- 1601 HIGHWAY 49B NORTH
- City
- PARAGOULD
- State
- AR
- ZIP
- 72450
- Mailing
- 1601 HIGHWAY 49B NORTH, PARAGOULD, AR 72450
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336330
- Employees
- 1000
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Nov 3, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $6,533 · Current $3,266 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about July 6, 2016, and times prior to, for the Rod Welders located in Department 13, written energy control procedures and training did not include specific steps to be followed for troubleshooting and activating the pneumatic air valve that introduces pressure to allow the jaw clamps inside the welders to retract. Employee activated the pneumatic air valve on Rod Welder 3, #4588, while an employee was performing troubleshooting tasks. Employee was exposed to the hazard of amputations.
Recent events (2)
- · I (O) $3266.3
- · Z (S) $6533
1910.212 A01
- Issued
- Nov 3, 2016
- Abate by
- Mar 10, 2017
- Penalty
- Initial $10,888 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about July 6, 2016, and times prior to, Department 13 Rod Welder area, the pneumatic air valves on the Rod Welders were not guarded to prevent unauthorized employee access. Unauthorized employees activated the pneumatic air valve on Rod Welder 3, #4588, which exposed employee to amputation hazards.
Recent events (2)
- · I (O) $4000
- · Z (S) $10888
More inspections at Tenneco, INC.
View Tenneco, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336330)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341604890.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.