HAMMONTON, NJ —
OSHA Inspection: KK INDUSTRIAL INCORPORATED
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of KK INDUSTRIAL INCORPORATED in 224 VINE ST, HAMMONTON, NJ 08037 (NAICS 333312). OSHA activity number 341615276.
Where did this inspection happen?
- Establishment
- KK INDUSTRIAL INCORPORATED
- Site address
- 224 VINE ST
- City
- HAMMONTON
- State
- NJ
- ZIP
- 08037
- Mailing
- 224 VINE ST, HAMMONTON, NJ 08037
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333312
- Employees
- 7
- Ownership type
- A
Citations
28 citations on file for this inspection.
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) West side of back building: The employer did not ensure that an employee used a face shield or goggles when adding corrosive chemicals to the washing machine, including, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $1000
- — C (S) $2672
- — Z (S) $2672
1910.138 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) West side of back building: The employer did not select and require employees to use appropriate hand protection when adding corrosive chemicals to the washing machine, including, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) West side of back building: An eyewash station capable of providing 15 minutes of continuous flushing was not provided where employees added corrosive chemicals to the washing machine, including, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Throughout facility: The employer did not develop, document and utilized energy control procedures, for equipment that is serviced or maintained by employees, such as, but not limited to, an Omega Built by G-M ironing machine, folding machine, a mangler, dryers and a G.A. Braun Incorporated washing machine, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Throughout facility: The employer did not conduct a periodic inspection of the energy control procedures for equipment that is serviced or maintained by employees, such as, but not limited to, an Omega Built by G-M ironing machine, folding machine, a mangler, dryers and a G.A. Braun Incorporated washing machine, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) Throughout facility: Training on the applicable hazardous energy sources, the type and magnitude of energy in the workplace and the means for energy isolation was not provided for authorized employees that serviced or maintained equipment, such as, but not limited to, an Omega Built by G-M ironing machine, folding machine, a mangler, dryers and a G.A. Braun Incorporated washing machine, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 I B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Throughout facility: Affected employees were not instructed in the purpose and use of the energy control procedures for equipment that is serviced or maintained by employees, such as, but not limited to, an Omega Built by G-M ironing machine, folding machine, a mangler, dryers and a G.A. Braun Incorporated washing machine, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.157 C04
- Issued
- Abate by
- Penalty
- Initial $1604.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places at all times except during use: a) Northwest side of front building: A portable fire extinguisher was not kept mounted where indicated by signage located next to the folding machine, on or about 7/13/16. b) West side of front building: A portable fire extinguisher was not kept mounted where indicated by signage located next to the ironing machine, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $1604
- — Z (S) $1604
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Throughout facility: The employer did not provide training on the general principles of fire extinguisher use and the hazards of incipient stage fire fighting upon hire and annually thereafter to employees required to use fire extinguishers, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Southwestend of front building: A window fan located next to the ironing machine was not guarded, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Northeast corner of the front building near door: A pulley operating a belt on a folding machine was not guarded, on or about 7/13/16. b) Southwestend of front building: A pulley operating a belt on a window fan at 1725 RPM was not guarded, on or about 7/13/16. c) South end of front building: A pulley operating a belt on the left side of the ironer was not guarded, on or about 7/13/16. d) West side of front building: A pulley operating a belt on the ironer at 1750 RPM next to the windows was not guarded, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.219 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) West side of front building: A pulley operating a belt on the ironer at 1750 RPM next to the windows was not guarded, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Northeast corner of the front building near door: A vertical belt on a pulley operating a folding machine was not guarded, on or about 7/13/16. b) South end of front building: A vertical belt on a pulley operating a belt on the left side of the ironer was not guarded, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 E04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(4): Vertical belts. Vertical belts running over a lower pulley more than seven (7) feet above floor or platform shall be guarded at the bottom in the same manner as horizontal overhead belts, if conditions are as stated in paragraphs (e)(2)(ii) (a) and (c) of this section: a) Southwest end of front building: The bottom portion of a vertical belt on a pulley operating a window fan at 1725 RPM was not guarded, on or about 7/13/16. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 F01
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) Northeast corner of the front building near doo: rGears operating the mangler machine were not guarded, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $2672
- — Z (S) $2672
1910.303 B06
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(6): Conductors located in wet or damp locations were not identified for that environment. a) West side back building: A G.A. Braun Inc washing machine operating at 208 volt and 45 amps had a damaged operational box exposing the internal bus bars to rain water from the damaged roof, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $2672
- — Z (S) $2672
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $1604.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) East side of front building: The space in front of the electrical disconnect switch for the washing machine operating at 208 volts was blocked by laundry bins, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $1604
- — Z (S) $1604
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) South end of the front building: An operational panel on the front left side of the ironing machine did not have a cover exposing employees to live bus bars, on or about 7/13/16. b) Northeast side of back building: An operational panel for the air compressor, operating at 230 volts, did not have a cover exposing employees to live bus bars, on or about 7/13/16. c) Southwest end of back building: An operational panel for the washing machine, operating at 208 volts, that contained the main electrical components for the machine had a broken cover exposing employees to live bus bars, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $2672
- — Z (S) $2672
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) South end of the front building: A junction box on the front left side of the ironing machine did not have a cover, on or about 7/13/16. b) Northeast side of back building: A junction box for the air compressor did not have a cover, on or about 7/13/16. c) Southwest end of back building: A junction box for the washing machine that contained the main electrical components for the machine had a broken cover, on or about 7/13/16. d) North end of front building: A junction box on the front of the dryer did not have a cover, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $1604.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) West side back building: A junction box on the washing machine had a missing knockout, on or about 7/13/16. b) Front side entrance to building: An electrical panel that powered equipment such as, but not limited to, a dryer, fan and folding machine, had an open unused slot, on or about 7/13/16. c) Front side entrance to building: An electrical panel that powered equipment such as, but not limited to, washing machines, a dryer, an air compressor and lights, had six unused open slots, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $1604
- — Z (S) $1604
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1604.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) East side of back building: An extension cord was used to operate a ceiling mounted light, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $1604
- — Z (S) $1604
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) East side of back building: An extension cord used to operate a ceiling mounted light had a torn strain relief, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2672.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) would be met: a) West side of back building: The employer did not develop and implement a written hazard communication program for the hazardous chemicals used in the facility, such as, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, corrosive chemicals, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $2672
- — Z (S) $2672
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemical in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) Washing department: The employer did not ensure that a five gallon bucket of bleach, a corrosive chemical, was labeled according to the standard, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which was used: a) West side of back building: The employer did not have safety data sheets for the hazardous chemicals used in the facility, such as, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, corrosive chemicals, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) West side of back building: The employer did not provide hazard communication training for the hazardous chemicals used in the facility, such as, but not limited to, Doctor Washer Heavy Duty Laundry Detergent, bleach and Jumbo Liquid Laundry Detergent, corrosive chemicals, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1904.39 A02
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: a) Throughout the facility: The employer did not report an in-patient hospitalization for an employee whose hand got pulled into a belt on an industrial washing machine, on or about 7/2/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $0
- — C (O) $1500
- — Z (O) $1500
1910.141 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: a) Bathroom: Visible mold was on the walls of the bathroom, on or about 7/13/16. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333312)
WESTWOOD, KY—2021-07-15 00:00:00
63967 - GREEN EARTH CLEANERS LLC
ROUND ROCK, TX—2020-09-14 00:00:00
PRUDENTIAL OVERALL SUPPLY
COLVILLE, WA—2020-07-24 00:00:00
WA317960310 - COLMAC INDUSTRIES INC
GUAYNABO, PR—2020-02-28 00:00:00
LUAR CLEANERS
NEW BEDFORD, MA—2020-02-25 00:00:00
CLEAN RENTALS INCORPORATED
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341615276.