OSHA Inspection: MIZE HEATING AND AIR, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MIZE HEATING AND AIR, INC. in 9 LAKESIDE LN, NEWPORT, AR 72112 (NAICS 238220). OSHA activity number 341619963.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mize Heating and AIR, INC. — free Get an email when a new federal OSHA severe-injury report for Mize Heating and AIR, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9 LAKESIDE LN
City
NEWPORT
State
AR
ZIP
72112
Mailing
311 W. PLEASURE ST, STE #2, SEARCY, AR 72143
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 26, 2016
Abate by
Sep 29, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  On or about July 14, 2016, at or near 9 Lakeside Lane, Newport, AR 72112, employees engaged in removing or replacing a drain pipe on a HVAC unit were exposed to electrical hazards in the following instances:    a. A bare electric wire was hanging from a thermostat on the rafters in the attic. b. A broken light bulb was hanging from the rafters in the attic.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12471

1926.1203 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 26, 2016
Abate by
Sep 29, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.1203(a): Before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary:  On or about July 13, 2016 at or near 9 Lakeside Ln, Newport, AR 72112, the employer did not ensure that a competent person evaluated and identified the attic with electrical hazards as a permit-required confined space.
Recent events (2)
  • — I (S) $4988
  • — Z (S) $4988

View Mize Heating and AIR, INC.'s full OSHA safety record →