Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEKTRONIX INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TEKTRONIX INC in 28775 AURORA ROAD, CLEVELAND, OH 44139 (NAICS 334515). OSHA activity number 341623502.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tektronix INC — free Get an email when a new federal OSHA severe-injury report for Tektronix INC is published. One employer, no account, unsubscribe in one click.
Establishment
TEKTRONIX INC
Site address
28775 AURORA ROAD
City
CLEVELAND
State
OH
ZIP
44139
Mailing
28775 AURORA RD., CLEVELAND, OH 44139
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334515
Employees
207
Ownership type
A

2 citations on file for this inspection.

1910.333 A02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jul 28, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved:  On or about July 6, 2016, the employer exposed employees to electrical hazards (800VDC) while working on a power supply calibration system for the Keithley model 2260B-800-1 test stand.  Other feasible safety related work practices were not implemented to ensure that the employee was aware of the potential exposure to live parts.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.335 A01 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jul 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:  On or about July 7, 2016, the employer exposed employees to electrical hazards (800VDC) by not ensuring that employees working on a power supply calibration system for the Keithley Model 2260B-800-1 test stand, were wearing heavy duty leather gloves.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Tektronix INC's full OSHA safety record →