Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SELECT-TRON INDUSTRIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SELECT-TRON INDUSTRIES, INC. in 1946 E 12TH STREET, ERIE, PA 16511 (NAICS 332813). OSHA activity number 341633634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Select-Tron Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Select-Tron Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1946 E 12TH STREET
City
ERIE
State
PA
ZIP
16511
Mailing
1946 E 12TH STREET, ERIE, PA 16511
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2016
Penalty
Initial $2,272 · Current $2,272
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a.) Select-Tron Industries, Inc., 1946 East 12th Steet, Erie, Pa, Eyewash in electroplating area, on or about July 20th , 2016, and times prior thereto:  Employees worked with and around corrosive chemicals including, but not limited to, Muriatic and Sulfuric Acids during electroplating operations.  The plumbed emergency eyewash station in the electroplating area was not in compliance with ANSI 358.1-2014 for Emergency Eyewash and Shower Equipment in that:   1.)  The eyewash station was not operational, in that, upon activation, the eyewash did not provide flushing fluid to the employee's eyes and face during activation.     2) Weekly inspections of the equipment were not conducted. The emergency eyewash unit was not activated weekly to verify proper operation.
Recent events (1)
  • — Z (S) $2272

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $1,604 · Current $1,604
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a.) Select-Tron Industries, Inc., 1946 East 12th Steet, Erie, Pa, Electroplating area/Muriatic acid tank area, on or about July 20th , 2016, and times prior thereto:  Employees utilized a flexible (extension) cord to power a Coffing brand 500 pound hoist in the electroplating area of the facility.  The flexible cord was used in lieu of the permanent wiring of the structure.
Recent events (1)
  • — Z (S) $1604

1910.303 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2016
Abate by
Nov 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:     a.) Select-Tron Industries, Inc., 1946 East 12th street, Erie, Pa, Electroplating area, on or about July 20th , 2016, and times prior thereto:  Employees utilized immersion heaters to heat water and acids onsite.  The conduit protecting the internal wiring of the Process Technology brand immersion heater (Model #QM2217-PQI) was disconnected/split exposing the internal wires of the heater.