CEDARVILLE, MI ·
OSHA Inspection: FLOATATION DOCKING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLOATATION DOCKING, INC. in 100 E HODECK ST, CEDARVILLE, MI 49719 (NAICS 713930). OSHA activity number 341637296.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLOATATION DOCKING, INC.
- Site address
- 100 E HODECK ST
- City
- CEDARVILLE
- State
- MI
- ZIP
- 49719
- Mailing
- 100 E HODECK ST P.O. BOX 392, CEDARVILLE, MI 49719
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713930
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.179 M01
- Issued
- Aug 8, 2016
- Abate by
- Sep 1, 2016
- Penalty
- Initial $1,604 · Current $1,123 Reduced
General-duty citation text
29 CFR 1910.179(m)(1): Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes: Cedarville Marine, the employer did not conduct monthly running rope inspections and did not maintain a written certification record for running rope inspections for 25 ton Marine Travelift, Model # 25 BFM, S/N 2868.300.
Recent events (2)
- · I (S) $1122.8
- · Z (S) $1604
1910.242 B
- Issued
- Aug 8, 2016
- Abate by
- Sep 1, 2016
- Penalty
- Initial $1,604 · Current $1,123 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: In the shop, an air nozzle used for cleaning purposes did not reduce the air pressure to 30 p.s.i. The air pressure was set at approximately 85 p.s.i., there by exposing employees to a struck by hazard. .
Recent events (2)
- · I (S) $1122.8
- · Z (S) $1604
1910.305 G02 III
- Issued
- Aug 8, 2016
- Abate by
- Sep 1, 2016
- Penalty
- Initial $1,604 · Current $1,123 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: In the boat house, a control cable attached to a hoist controller used to operate a Coffing Electric boat hoist did not have adequate strain relief in that the control cable was pulled from the control box there by exposing employees to electrical hazards.
Recent events (2)
- · I (S) $1122.8
- · Z (S) $1604
1915.502 A
- Issued
- Aug 8, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $2,138 · Current $1,497 Reduced
General-duty citation text
29 CFR 1915.502(a): A written fire safety plan was not developed and implemented by the employer that covered all of the actions necessary to ensure the employees safety in the event of a fire. Cedarville Marine, the employer failed to develop and implement an adequate fire safety plan that covered all of the actions necessary to ensure employees safety in the event of a fire.
Recent events (2)
- · I (S) $1496.6
- · Z (S) $2138
More inspections in this industry (NAICS 713930)