MESHOPPEN, PA —
OSHA Inspection: LHC CONSTRUCTION MANAGEMENT, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of LHC CONSTRUCTION MANAGEMENT, LLC in 8822 SR 3001, MESHOPPEN, PA 18630 (NAICS 236118). OSHA activity number 341640332.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LHC CONSTRUCTION MANAGEMENT, LLC
- Site address
- 8822 SR 3001
- City
- MESHOPPEN
- State
- PA
- ZIP
- 18630
- Mailing
- 1212 KEELERSBURG RD, TUNKHANNOCK, PA 18657
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.106 A
- Issued
- Jan 13, 2017
- Penalty
- Initial $2,672 · Current $0 Reduced
General-duty citation text
29 CFR 1926.106(a): Employees working over or near water where the danger of drowning existed, were not provided with U.S. Coast Guard approved life jackets or buoyant work vests. a) Boathouse, Pole 131, Harveys Lake, PA - Employees were working over and near a lake with water depths ranging from one to more than fifteen feet and were not provided a life jacket or buoyant work vest while performing construction activities along the dock area, exposing employees to a drowning hazard, on or about July 21, 2016.
Recent events (3)
- — F (S) $0
- — C (S) $2672
- — Z (S) $2672
1926.403 B02
- Issued
- Jan 13, 2017
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. a) Renovated Boathouse, Pole 131, Lakeside Drive, Harveys Lake, PA - An electrical subpanel was installed with an intact "bonding screw" which connected (bonded) a grounded conductor (neutral) to the grounding conductor on the load side of the main disconnect exposing employees to electrical hazards, as observed on or about July 21, 2016.
Recent events (3)
- — F (S) $12471
- — C (S) $12471
- — Z (S) $12471
1926.404 F06
- Issued
- Jan 13, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) Renovated boathouse, deck and dock, Pole 131, Lakeside Drive, Harveys Lake, PA - The path to ground for each receptacle was not permanent and continuous exposing employees to an electrical hazard, on or about July 21, 2016.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1926.404 F07 IV C 2
- Issued
- Jan 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(7)(iv)(C)(2): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which may become energized were not grounded when used in damp or wet locations: a) Shore side boat lift, Pole 131, Lakeside Drive, Harveys Lake, PA - The boat lift hoist motor (East Bay Model 1.0Tess 1-HP Motor Serial No. 30687) installed above water and the partially submerged boat lift hoist cable were not grounded exposing employees to an electrical hazard, on or about July 21, 2016. b) Lake side boat lift, Pole 131, Lakeside Drive, Harveys Lake, PA The boat lift hoist motor (East Bay Model 1.0Tess 1-HP Motor Serial No. 31669) installed above water and the partially submerged boat lift hoist cable were not grounded exposing employees to an electrical hazard, on or about July 21, 2016.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.403 H
- Issued
- Jan 13, 2017
- Penalty
- Initial $3,741 · Current $3,741
General-duty citation text
29 CFR 1926.403(h): Each service, feeder, and branch circuit was not legibly marked at its disconnecting means or overcurrent device to indicate its purpose, nor located and arranged so that the purpose was evident. a) Boathouse, Pole 131, Lakeside Drive, Harveys Lake, PA - Energized branch circuits were serviced by incorrectly identified overcurrent devices (Circuit Breakers #11 and #13) on the electrical subpanel door exposing employees to electrical hazards, as observed on or about July 21, 2016.
Recent events (3)
- — F (S) $3741
- — C (S) $3741
- — Z (S) $3741
More inspections at LHC Construction Management, LLC
View LHC Construction Management, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341640332.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.