Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DECOSTAR INDUSTRIES INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DECOSTAR INDUSTRIES INC. in 1 DECOMA DRIVE, CARROLLTON, GA 30117 (NAICS 336390). OSHA activity number 341640399.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Decostar Industries INC. — free Get an email when a new federal OSHA severe-injury report for Decostar Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 DECOMA DRIVE
City
CARROLLTON
State
GA
ZIP
30117
Mailing
1 DECOMA DRIVE, CARROLLTON, GA 30117
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
1080
Ownership type
A

5 citations on file for this inspection.

1910.22 A02

Other-than-serious 1 instance 14 exposed
Issued
Jan 12, 2017
Penalty
Initial $7,126 · Current $0 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) Top of Basement stairs; The employer allowed condensate water to accumulate on the floor creating a slip and trip hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7126

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $8,908 · Current $6,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    a) Basement; The employer exposed maintenance employees to fall hazards while looking for leaks on the purge lines on the maintenance platform at Drive 2 at a height of approximately 8 feet 3/8 inches above the lower level without fall protection.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $8908

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 12, 2017
Penalty
Initial $12,471 · Current $8,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Basement; the motorized drive belts on Drives #1, 2 and 3 were unguarded exposing the employees to amputation hazards created by rotating parts.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12471

1910.1200 H03 I

Repeat Gravity 5 1 instance 14 exposed
Issued
Jan 12, 2017
Abate by
Feb 1, 2017
Penalty
Initial $44,540 · Current $34,000 Reduced
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area:    a) Basement; The employer failed to provide training on the methods and observations used to detect the presence or release of a hazardous chemical, Spectraclean Purge (category 2 flammable liquid and vapor, toxin).    Decostar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(h)(3)(i), which was contained in OSHA inspection number 1040283 citation number 1, item number 1 and was affirmed as a final order on May 28, 2015, with respect to a workplace located at 1 Decoma Dr., Carrollton, GA 30117.
Recent events (2)
  • — I (R) $34000
  • — Z (R) $44540

1910.1200 H03 II

Repeat Gravity 5 1 instance 14 exposed
Issued
Jan 12, 2017
Abate by
Feb 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:  a) Basement; The employer allowed employees to work with potentially hazardous chemicals such as, but not limited to Spectraclean Purge (category 2 flammable liquid and vapor, toxin) without training, exposing employees to physical and health hazards.  Decostar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(h)(3)(ii), which was contained in OSHA inspection number 952323 citation number 1, item number 1 and was affirmed as a final order on May 27, 2014, with respect to a workplace located at 1 Decoma Dr., Carrollton, GA 30117.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Decostar Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341640399.