CARROLLTON, GA —
OSHA Inspection: DECOSTAR INDUSTRIES INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of DECOSTAR INDUSTRIES INC. in 1 DECOMA DRIVE, CARROLLTON, GA 30117 (NAICS 336390). OSHA activity number 341640399.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DECOSTAR INDUSTRIES INC.
- Site address
- 1 DECOMA DRIVE
- City
- CARROLLTON
- State
- GA
- ZIP
- 30117
- Mailing
- 1 DECOMA DRIVE, CARROLLTON, GA 30117
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 1080
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A02
- Issued
- Jan 12, 2017
- Penalty
- Initial $7,126 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: a) Top of Basement stairs; The employer allowed condensate water to accumulate on the floor creating a slip and trip hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $7126
1910.23 C01
- Issued
- Jan 12, 2017
- Penalty
- Initial $8,908 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Basement; The employer exposed maintenance employees to fall hazards while looking for leaks on the purge lines on the maintenance platform at Drive 2 at a height of approximately 8 feet 3/8 inches above the lower level without fall protection.
Recent events (2)
- — I (S) $6000
- — Z (S) $8908
1910.212 A01
- Issued
- Jan 12, 2017
- Penalty
- Initial $12,471 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Basement; the motorized drive belts on Drives #1, 2 and 3 were unguarded exposing the employees to amputation hazards created by rotating parts.
Recent events (2)
- — I (S) $8000
- — Z (S) $12471
1910.1200 H03 I
- Issued
- Jan 12, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $44,540 · Current $34,000 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area: a) Basement; The employer failed to provide training on the methods and observations used to detect the presence or release of a hazardous chemical, Spectraclean Purge (category 2 flammable liquid and vapor, toxin). Decostar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(h)(3)(i), which was contained in OSHA inspection number 1040283 citation number 1, item number 1 and was affirmed as a final order on May 28, 2015, with respect to a workplace located at 1 Decoma Dr., Carrollton, GA 30117.
Recent events (2)
- — I (R) $34000
- — Z (R) $44540
1910.1200 H03 II
- Issued
- Jan 12, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: a) Basement; The employer allowed employees to work with potentially hazardous chemicals such as, but not limited to Spectraclean Purge (category 2 flammable liquid and vapor, toxin) without training, exposing employees to physical and health hazards. Decostar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(h)(3)(ii), which was contained in OSHA inspection number 952323 citation number 1, item number 1 and was affirmed as a final order on May 27, 2014, with respect to a workplace located at 1 Decoma Dr., Carrollton, GA 30117.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Decostar Industries INC.
View Decostar Industries INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336390)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341640399.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.