Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KINGS OF ST. NICHOLAS INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KINGS OF ST. NICHOLAS INC. in 552 WEST 182ND STREET, NEW YORK, NY 10033 (NAICS 448190). OSHA activity number 341643369.

Watch Kings OF ST. Nicholas INC. — free Get an email when a new federal OSHA severe-injury report for Kings OF ST. Nicholas INC. is published. One employer, no account, unsubscribe in one click.
Site address
552 WEST 182ND STREET
City
NEW YORK
State
NY
ZIP
10033
Mailing
333 EARLE OVINGTON BLVD, SUITE 1010, UNIONDALE, NY 11553
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
448190
Employees
3
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12675.00 · Current $11675.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushed by hazards.    Site: 552 West 182nd Street New York NY    On or about 7/23/16    a) An employee operated the dumbwaiter system.  Doors to the hoistway were open when the dumbwaiter was in operation.  Employees were exposed to the hazard of being struck by or crushed by the dumbwaiter..    Among other methods, several feasible and acceptable abatement methods to correct hazards are to:    Comply with ASME A17.1-2016/CSA B44-13, Safety Code For Elevators and Escalators (Includes Requirements for Elevators, Escalators, Dumbwaiters, Moving Walks, Material Lifts, and Dumbwaiters With Automatic Transfer Devices)    Section 7.2 Electric And Hand Dumbwaiters Without Automatic Transfer Devices states that Car enclosures and car doors and gates shall comply with 2.14,.   Section 2.14.1.4.6 page 58 states,  all hoistway doors shall be closed and locked and the car doors for each compartment closed before the car can be operated.  Section 2.14.4.11 page 63 states, car doors or gates shall be considered to be in the closed position under the following condition: a) for horizontally sliding doors or gates, when the clear open space between the leading edge of the door or gate and the nearest face of the jamb does not exceed 50 mm (2in.) except where car doors are provided with a car door interlocks, 10 mm (0.375 in).   Section 2.12.2.2 page 48 and section 2.12.3.2 also refers to Section 2.14.4.6 and to section 2.14.4.11 "car doors or gates shall be in the closed position).   Section 7.2.1.2 page 251 states, Car door or gates shall be provided at entrances to the car, shall guard the full width of the opening and shall conform to 7.2.1.2.1 through 7.2.1.2.12.  Section 7.2.1.2.2 page 251 states, Each door or gate shall be equipped with a contact that will prevent operation of the driving machine, unless the door gate panels is in the closed position as defined in 2.12.2.2 or 2.12.3.2.  Section 7.2.1.2.12 page 251 states, Where car door or gate horizontal structural members are not fixed to the moveable panel, they shall not be capable of entering into the access door area.
Recent events (3)
  • — R (S) $11675
  • — C (S) $12675
  • — Z (S) $12675

1910.23 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3155.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards.     Site: 552 West 182nd Street New York, NY    On or about 7/23/16    a) Employees working/walking by the 2nd floor stairway were exposed to fall hazards from approximately 11 feet high.
Recent events (3)
  • — R (S) $3155
  • — C (S) $3803
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341643369.