Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: BOSTON BLUE REALTY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOSTON BLUE REALTY, LLC in 38 GREENDALE ROAD, MATTAPAN, MA 02126 (NAICS 236116). OSHA activity number 341644136.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boston Blue Realty, LLC for free Get an email when a new federal OSHA severe-injury report for Boston Blue Realty, LLC is published. One employer, no account, unsubscribe in one click.
Site address
38 GREENDALE ROAD
City
MATTAPAN
State
MA
ZIP
02126
Mailing
45 NEPONSET AVENUE, DORCHESTER, MA 02122
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 16, 2016
Penalty
Initial $2,672 · Current $780 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    Side of building:  A pump-jack scaffold system with four (4) poles was erected approximately forty (40) feet tall where the base of the poles were resting on the ground and a non-flat rock.  This exposed the employees to fall and struck-by hazards from shifting or collapsing scaffolding.
Recent events (3)
  • · F (S) $780
  • · C (S) $2672
  • · Z (S) $2672

1926.451 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 16, 2016
Penalty
Initial $2,672 · Current $780 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.    Side of the house:  A pole for a pump-jack scaffold system had been erected approximately eight (8) inches from the live home electrical service line exposing employees to electrocution and fall hazards.
Recent events (3)
  • · F (S) $780
  • · C (S) $2672
  • · Z (S) $2672

1926.451 F07

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 16, 2016
Penalty
Initial $2,672 · Current $780 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    Side of house:  A pump-jack scaffold system had been erected with poles approximately forty (40) feet tall without bottom or mid bracing, without mud sills, and without being plumb.  The erection was not supervised by a competent person exposing employees to fall and struck-by hazards from collapsing scaffolding.
Recent events (3)
  • · F (S) $780
  • · C (S) $2672
  • · Z (S) $2672

1926.452 J02

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 16, 2016
Penalty
Initial $3,741 · Current $1,080 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    Side of building:  Poles used for pump-jack scaffolding approximately forty (40) feet tall were not secured to the structure at the bottom or other points as required allowing the employees to move the bottom of the poles close to the building exposing them to fall and struck-by hazards.
Recent events (3)
  • · F (S) $1080
  • · C (S) $3741
  • · Z (S) $3741

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2016
Abate by
Nov 7, 2016
Penalty
Initial $3,741 · Current $1,080 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a)  Jobsite third floor balcony:  An employee was exposed to a fall of approximately thirty-seven (37) feet to the ground below while working on the fascia without the use of fall protection.
Recent events (3)
  • · F (S) $1080
  • · C (S) $3741
  • · Z (S) $3741

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341644136.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.