Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SILVER DOLLAR FENCE CO, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SILVER DOLLAR FENCE CO, LLC in 291 REBEL DRIVE, UNIVERSITY, MS 38677 (NAICS 238990). OSHA activity number 341648657.

Watch Silver Dollar Fence CO, LLC — free Get an email when a new federal OSHA severe-injury report for Silver Dollar Fence CO, LLC is published. One employer, no account, unsubscribe in one click.
Site address
291 REBEL DRIVE
City
UNIVERSITY
State
MS
ZIP
38677
Mailing
62 NORTH ROAD, ECRU, MS 38841
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.351 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3029.00 · Current $3029.00
29 CFR 1926.351(b)(2): Welding cable in use was not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected:  (a) West Jobsite - On or about July 26, 2016 employee used a Hobart portable welder with exposed connectors less than 10 feet from the electrode holder. The exposed connector was 36 inches from the electrode holder.
Recent events (1)
  • — Z (S) $3029

1926.351 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.351(b)(4): Cables in need of repair shall not be used. When a cable, other than the cable lead referred to in paragraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tape or other equivalent insulation.  (a) West Jbsite - On or about July 26, 2016 employee used a Hobart portable welder with damaged electrical insulation which exposed copper wiring where the lead connects to the welder.
Recent events (1)
  • — Z (S) $0

1926.405 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2423.00 · Current $2423.00
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:  (a) West Jobsite - On or about July 26, 2016 employees used a portable 4 1/2 inch Dewalt grinder with a spiced power cord.
Recent events (1)
  • — Z (S) $2423

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341648657.