Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: OWENS ILLINOIS INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OWENS ILLINOIS INC in 1 MICHAEL OWENS WAY PLAZA ONE, PERRYSBURG, OH 43551 (NAICS 327213). OSHA activity number 341654457.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Owens Illinois INC for free Get an email when a new federal OSHA severe-injury report for Owens Illinois INC is published. One employer, no account, unsubscribe in one click.
Establishment
OWENS ILLINOIS INC
Site address
1 MICHAEL OWENS WAY PLAZA ONE
City
PERRYSBURG
State
OH
ZIP
43551
Mailing
1 MICHAEL OWENS WAY, PERRYSBURG, OH 43551
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327213
Employees
900
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 10, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Owens Illinois, Inc. on or about July 26, 2016, at the site located at 1 Michael Owens Way (plaza #1) Perrysburg, OH: The employer did not ensure that machine specific energy control procedures were developed and utilized to control potentially hazardous energy sources while an employee performed service and maintenance work on the roof top mounted Air Handler Unit #2. The employee performing this activity in a condition in which electric and mechanical energy was not isolated, was exposed to incoming nip points at the air handlers belt and pulley drives.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12471

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 10, 2016
Penalty
Initial $0 · Current $12,471
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    a)  Owens Illinois, Inc. on or about July 26, 2016, at the site located at 1 Michael Owens Way (plaza #1) Perrysburg, OH: The employer failed to ensure that hazardous energy sources such as, electrical and mechanical potential were physically isolated before employees performed service and maintenance work at or near belt and pulley drive(s) contained in the roof mounted Air Handler Unit #2. An employee performing this activity in an uncontrolled condition was exposed to incoming nip points at the units drive belt and pulley, in that energy isolation devices required under 29 CRF 1910.147(d)(3) were not utilized before the employee began the aforementioned work task.
Recent events (2)
  • · I (S) $12471
  • · Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 10, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) Owens Illinois, Inc. on or about July 26, 2016, at the site located at 1 Michael Owens Way (plaza #1) Perrysburg, OH: The employer failed to ensure that maintenance employees tasked with service and maintenance activities at or near energized parts of the roof mounted air handler units were adequately trained in the skills required for the safe application, usage, methods, and means of isolating and controlling hazardous energy sources. Employees tasked with service work on the aforementioned machine were not specifically trained to lockout the machine to protect against amputation injuries prior to performing work at or near nip points and moving parts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12471

View Owens Illinois INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341654457.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.