Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: B & D ROOFING OF CENTRAL FLORIDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B & D ROOFING OF CENTRAL FLORIDA, INC. in 2465 OXFORD ROAD, DELAND, FL 32720 (NAICS 238160). OSHA activity number 341654564.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & D Roofing of Central Florida, INC. — free Get an email when a new federal OSHA severe-injury report for B & D Roofing of Central Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2465 OXFORD ROAD
City
DELAND
State
FL
ZIP
32720
Mailing
1955 S SPRING GARDEN AVE., DELAND, FL 32720
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 10, 2016
Abate by
Aug 18, 2016
Penalty
Initial $2,138 · Current $1,283 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a. On or about July 27, 2016, employees operating nail guns and saw were not wearing safety glasses and were being exposed to eye injuries.
Recent events (2)
  • — I (S) $1282.8
  • — Z (S) $2138

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 10, 2016
Penalty
Initial $8,730 · Current $5,238 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  a. On or about July 27, 2016, employees tearing off an old roof system on a 6:12 pitch roof were not protected from falling 10 feet by the use of a fall protection system.
Recent events (2)
  • — I (S) $5238
  • — Z (S) $8730

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341654564.