Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JACK A FARRIOR INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JACK A FARRIOR INC. in 9200 E 90TH AVENUE, HENDERSON, CO 80640 (NAICS 238220). OSHA activity number 341659621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jack a Farrior INC. — free Get an email when a new federal OSHA severe-injury report for Jack a Farrior INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JACK A FARRIOR INC.
Site address
9200 E 90TH AVENUE
City
HENDERSON
State
CO
ZIP
80640
Mailing
PO BOX 839, FARMVILLE, NC 27828
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
17
Ownership type
A

5 citations on file for this inspection.

1926.501 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 21, 2016
Abate by
Oct 11, 2016
Penalty
Initial $4,240 · Current $2,968 Reduced
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structural integrity to support employees safely:    (a)  Jack A. Farrior Inc, at 9200 E 90th Avenue, Henderson, CO: On or about 7/29/16, Jack A. Farrior Inc did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structural integrity to support employees safely.  Employees were disassembling a cooler, which consisted of top, side, and belly panels.  The cooler sections were supported by beams anchored in a concrete floor, approximately eight feet below.  While disassembling the cooler, employees stood upon the belly pans.  The bolts securing the belly pans had been removed prior to work resuming during the night shift on 7/29/16 into 7/30/16.  While dragging a side panel across a section of belly panel, the belly panel collapsed, causing two workers to fall to the concrete floor below.  The employer had not determined if the belly pans had the strength and structural integrity to support the workers.  This condition exposed employees to an approximate eight foot fall hazard.
Recent events (2)
  • — I (S) $2968
  • — Z (S) $4240

1926.502 B01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Sep 21, 2016
Abate by
Oct 11, 2016
Penalty
Initial $3,180 · Current $0 Reduced
29 CFR 1926.502(b)(1):  The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  (a)  Jack A. Farrior Inc, at 9200 E 90th Avenue, Henderson, CO: On and preceding 7/30/16, Jack A. Farrior Inc did not ensure that the top edge height of the top rails, or equivalent guardrail system members, was 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level.  Employees were disassembling a cooler, which consisted of top, side, and belly panels.  The cooler sections were hoisted from the basement to the first floor through a floor opening.  Wire rope with colored tape was secured approximately three feet from the sides of the floor opening to act as a guardrail.  The heights of the wire ropes were measured at 30.5" and 33.5".  This condition exposed employees to an approximate sixteen foot fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3180

1926.502 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 21, 2016
Abate by
Oct 20, 2016
Penalty
Initial $0 · Current $2,226
29 CFR 1926.502(b)(2):  Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high:    (a)  Jack A. Farrior Inc, at 9200 E 90th Avenue, Henderson, CO: On and preceding 7/30/16, Jack A. Farrior Inc did not ensure that midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high.  Employees were disassembling a cooler, which consisted of top, side, and belly panels.  The cooler sections were hoisted from the basement to the first floor through a floor opening.  Wire rope with colored tape was secured approximately three feet from the sides of the floor opening to act as a guardrail.  A mid-rail or other intermediate structural member was not installed between the wire rope and the walking surface.  This condition exposed employees to an approximate sixteen foot fall hazard.
Recent events (2)
  • — I (S) $2226
  • — Z (S) $0

1926.502 D23

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2016
Abate by
Oct 11, 2016
Penalty
Initial $4,240 · Current $2,968 Reduced
29 CFR 1926.502(d)(23):  Personal fall arrest systems were attached to guardrail systems or to hoists:    (a)  Jack A. Farrior Inc, at 9200 E 90th Avenue, Henderson, CO: On or about 7/30/16, Jack A. Farrior Inc did not ensure that a personal fall arrest system was not attached to a guardrail system.  Employees were disassembling a cooler, which consisted of top, side, and belly panels.  The cooler sections were supported by beams anchored in a concrete floor, approximately eight feet below.  While disassembling the cooler, one employee stood upon an elevator leg outside the south end catwalk's guardrail system.  The employee's personal fall arrest system was attached to the catwalk's guardrail system.  This condition exposed the employee to an approximate eight foot fall hazard.
Recent events (2)
  • — I (S) $2968
  • — Z (S) $4240

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Sep 21, 2016
Abate by
Oct 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that each powered industrial truck operator's performance was evaluated at least once every three years:  (a)  Jack A. Farrior Inc, at 9200 E 90th Avenue, Henderson, CO: On 8/1/16, Jack A. Farrior Inc did not ensure that each powered industrial truck operator's performance was evaluated at least once every three years.  Employees were disassembling a cooler, which consisted of top, side, and belly panels.  A Mitsubishi model FG50CN powered industrial truck was used to transport cooler sections and other materials at the jobsite.  An operator of the powered industrial truck last received training on 10/31/12. The employer had not evaluated the operator's performance at least once every three years.  This condition potentially exposed employees to a struck-by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Jack a Farrior INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341659621.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.