NESCOPECK, PA —
OSHA Inspection: RAD ENGINEERED WOOD PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RAD ENGINEERED WOOD PRODUCTS in 531 MAPLE ST., NESCOPECK, PA 18635 (NAICS 321918). OSHA activity number 341661015.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAD ENGINEERED WOOD PRODUCTS
- Site address
- 531 MAPLE ST.
- City
- NESCOPECK
- State
- PA
- ZIP
- 18635
- Mailing
- PO BOX 531, NESCOPECK, PA 18635
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 80
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.36 B01
- Issued
- Aug 18, 2016
- Abate by
- Oct 5, 2016
- Penalty
- Initial $3,181 · Current $2,386 Reduced
General-duty citation text
29 CFR 1910.36(b)(1): The exit routes were not located as far away as practical from each other so that if one exit route was blocked by fire or smoke, employees can evacuate using the second exit route: a) Production area: The two (2) emergency exits, located along the west side of the building, were not located as far away as practical from each other, as observed on or about August 1, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $2385.75
- — Z (S) $3181
1910.36 G02
- Issued
- Aug 18, 2016
- Abate by
- Oct 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a) Production area: The walkway platform used as part of the emergency exit route was measured at 20 inches wide, as observed on or about August 1, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 B01
- Issued
- Aug 18, 2016
- Abate by
- Oct 5, 2016
- Penalty
- Initial $3,181 · Current $2,386 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: a) Trim area: Access to and from the trim saw operator positions was partially obstructed by moving conveyor flight chains and wood trim pieces creating a potential trip and fall hazard, as observed on or about August 1, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $2385.75
- — Z (S) $3181
1910.213 B06
- Issued
- Aug 18, 2016
- Abate by
- Oct 5, 2016
- Penalty
- Initial $3,181 · Current $2,386 Reduced
General-duty citation text
29 CFR 1910.213(b)(6): Operating treadle(s) on woodworking machine(s) were not protected against unexpected or accidental tripping: a) Trim area: The operating pedal on trim saw #10 was not protected against unexpected or accidental tripping, as observed on or about August 1, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $2385.75
- — Z (S) $3181
More inspections at RAD Engineered Wood Products
View RAD Engineered Wood Products's full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341661015.