BRENTWOOD, NH —
OSHA Inspection: MTI POLYEXE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MTI POLYEXE, INC. in 50 PINE ST., BRENTWOOD, NH 03833 (NAICS 325211). OSHA activity number 341661031.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MTI POLYEXE, INC.
- Site address
- 50 PINE ST.
- City
- BRENTWOOD
- State
- NH
- ZIP
- 03833
- Mailing
- 50 PINE ST., BRENTWOOD, NH 03833
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 8000
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.95 C01
- Issued
- Sep 20, 2016
- Abate by
- Nov 7, 2016
- Penalty
- Initial $8,908 · Current $3,340 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) Location: PX2 On or about 8/1/16, Employees operating the PX2 machine during 12 hour shifts were exposed to noise at 70% of the action level which is equivalent to 87.4 dBA over an 8 hour time weighted average. Sampling was conducted for 416 minutes and the employer did not administer a hearing conservation program. The action level adjustment for 12 hour shift exposure for a 50% dose is 82.1 dBA TWA. (b) Location: MTI Coating On or about 8/1/16, employees operating the MTI coating machine were exposed to noise at 58% of the action level which is equivalent to 86 dBA over an 8 hour time weighted average. Sampling was conducted for 323 minutes and the employer did not have a hearing conservation program. The action level adjustment for 12 hour shift exposure for a 50% dose is 82.1 dBA TWA.
Recent events (2)
- — I (S) $3340
- — Z (S) $8908
1910.176 B
- Issued
- Sep 20, 2016
- Penalty
- Initial $8,908 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: (b) Location: facility On or about 7/12/16, storage shelves loaded by means of a fork lift were not anchored to the floor.
Recent events (2)
- — I (O) $0
- — Z (S) $8908
1910.178 L01 I
- Issued
- Sep 20, 2016
- Abate by
- Nov 7, 2016
- Penalty
- Initial $8,908 · Current $3,340 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Location: site On or about 8/1/16, the employer did not ensure employees operating a Nissan forklift model MAP1F2A25LV were trained and evaluated to safely operate the forklift.
Recent events (2)
- — I (S) $3340
- — Z (S) $8908
1910.212 A01
- Issued
- Sep 20, 2016
- Abate by
- Jan 2, 2017
- Penalty
- Initial $8,909 · Current $8,909
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Location: MTI coating machine On or about 8/1/16, employees were not protected from in-going nip points on the coating head and re-winder roll.
Recent events (2)
- — I (S) $8909
- — Z (S) $8909
1910.253 B04 I
- Issued
- Sep 20, 2016
- Penalty
- Initial $5,345 · Current $2,010 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; Location: PX2 room On or about 8/1/16, a compressed oxygen cylinder was stored next to an acetylene fuel gas cylinder.
Recent events (2)
- — I (S) $2010
- — Z (S) $5345
1910.303 B01
- Issued
- Sep 20, 2016
- Abate by
- Oct 7, 2016
- Penalty
- Initial $8,908 · Current $3,340 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: Location: second level of the PX2 On or about 8/1/16, employees were not protected from contacting live electrical parts while working in close proximity of an energized 480 volt electrical cabinet with the doors open.
Recent events (2)
- — I (S) $3340
- — Z (S) $8908
1910.305 A02 V C
- Issued
- Sep 20, 2016
- Penalty
- Initial $8,909 · Current $3,340 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(v)(C): Branch-circuit conductors were laid on the floor. Location: MTI Coating machine On or about 8/1/16, a conductor supplying 480 volt power to the trim blower motor was laid on the floor unguarded
Recent events (2)
- — I (S) $3340
- — Z (S) $8909
1910.305 B01 II
- Issued
- Sep 20, 2016
- Abate by
- Oct 17, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in electrical boxes, cabinets, or fittings were not effectively closed: Location: On the south wall in PX2 room On or about 8/1/16, a 24 inch long opening in a 480 volt energized electrical panel was covered using cardboard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Sep 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Location: trim blower in MTI area On or about 8/1/16, a flexible cord was used to supply power to a permanently mounted 480 volt blower motor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 325211)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341661031.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.