Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMMITMENT 2000 INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COMMITMENT 2000 INC. in 105 MONSIGNOR VALENTE DRIVE, BUFFALO, NY 14206 (NAICS 311812). OSHA activity number 341666121.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commitment 2000 INC. — free Get an email when a new federal OSHA severe-injury report for Commitment 2000 INC. is published. One employer, no account, unsubscribe in one click.
Site address
105 MONSIGNOR VALENTE DRIVE
City
BUFFALO
State
NY
ZIP
14206
Mailing
105 MONSIGNOR VALENTE DRIVE, BUFFALO, NY 14206
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
65
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 28, 2016
Abate by
Oct 31, 2016
Penalty
Initial $7,483 · Current $5,612 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about 08/04/16 throughout the location; employees cleared jams from machines and installed finger chutes at or near the point of operation on the conveyors found at the discharge end on T-2 line without using the written Machine Specific Lockout Tagout procedures.    ABATEMENT CERTIFICATION REQURIED
Recent events (2)
  • — I (S) $5612.25
  • — Z (S) $7483

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 28, 2016
Abate by
Nov 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   a) On or about 08/04/16 on T-2 line; authorized employees were not trained on the use of written lockout/tagout procedures when clearing dough ball jams on the T-2 line. An employee attempted to reinstall the slide chute while the conveyor was running and did not recognize the need to shut off and lockout the equipment before performing this activity.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 28, 2016
Penalty
Initial $7,483 · Current $5,612 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) On or about 07/28/16 at the discharge end of the T-2 line; employees were exposed to a caught in hazard of the moving conveyor belts when both access doors/guards on the discharge end of the Lawrence Equipment brand cooling conveyor were not installed.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $5612.25
  • — Z (S) $7483

1910.333 C02

Other-than-serious 1 instance 3 exposed
Issued
Sep 28, 2016
Abate by
Oct 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): Persons who were not qualified worked on or near electrical circuit parts or equipment that had not been de-energized under the procedures of paragraph (b) of this section. Such persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials and insulated tools.  a) On or about 08/04/16 at Line T-2 ; employees were exposed to contact with electrical current (460 volts AC) when the control panel door for the index control panel near the end of Line T-2 was open and employees were going inside the cabinet to store and retrieve and a computer mouse.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Commitment 2000 INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341666121.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.