FAR ROCKAWAY, NY —
OSHA Inspection: SINGH HARDWOOD COMPANY, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of SINGH HARDWOOD COMPANY, INC. in 5001 ROCKAWAY BEACH BLVD., FAR ROCKAWAY, NY 11691 (NAICS 321918). OSHA activity number 341668366.
Where did this inspection happen?
- Establishment
- SINGH HARDWOOD COMPANY, INC.
- Site address
- 5001 ROCKAWAY BEACH BLVD.
- City
- FAR ROCKAWAY
- State
- NY
- ZIP
- 11691
- Mailing
- 5001 ROCKAWAY BEACH BLVD., FAR ROCKAWAY, NY 11691
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 6
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1521.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The Dayton Industrial Motors Model 5K966J air compressor lacked a guard over its pulleys. (b) On or about January 6, 2017, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The Dayton Industrial Motors Model 5K966J air compressor lacked a guard over its pulleys. (c) On or about January 6, 2017, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The pulley on the sharpener of the Northfield Model 240 Planer lacked a guard. The pulley itself is powered by a dedicted Toshiba World Power Series 3-Phase Induction Motor, Type IK Form FOKLK. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (S) $1521
- — Z (S) $2173
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The Dayton Industrial Motors Model 5K966J air compressor lacked a guard over its belt. (b) On or about January 6, 2017, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The Dayton Industrial Motors Model 5K966J air compressor lacked a guard over its belt. (c) On or about January 6, 2017, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The belt on the sharpener of the Northfield Model 240 Planer lacked a guard. The pulley and belt themselves are powered by a dedicted Toshiba World Power Series 3-Phase Induction Motor, Type IK Form FOKLK. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $1141.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and effective chip guarding and personal protective equipment was not used. (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 Employees used compressed air delivered at 45-50 p.s.i. to clean clothing and machinery in the woodworking and dust collection section of the building. Chip guards were not provided on the air guns. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (S) $1141
- — Z (S) $1630
1910.307 C
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $1901.00 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The power switch located on the south wall, adjacent to the west end of the fine dust collection box, which supplies energy to the Dayton Industrial Motors Model 5K966J air compressor, was not suitable for use in a Class II Division 2 Hazardous Location in that it not only lacked a cover plate, but had other openings such as screw slots which could allow combustible wood dust, which is collected and was accumulating in the immediate vicinity, to potentially come into contact with live parts. (b) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The spiral metal electrical conduit connecting the Marathon Electric Series E Model 7VH 326TTDC4026AA S motor, which powers the Carolina Blower Model 55-6-SD fan, to the electrical supply was damaged. The resulting gap in the conduit allowed combustible wood dust to infiltrate and accumulate inside the conduit and possibly the motor itself, where it could come into contact with live parts, meaning it was unsuitable for a Class II Division 2 Hazardous Location. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (S) $1901
- — Z (S) $2716
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The spiral metal electrical conduit connecting the Marathon Electric Series E Model 7VH 326TTDC4026AA S motor, which powers the Carolina Blower Model 55-6-SD fan, to the electrical supply was damaged. The resulting gap in the conduit could lead to contact with live parts. WRITTEN CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The power switch located on the south wall, adjacent to the west end of the fine dust collection box, which supplies energy to the Dayton Industrial Motors Model 5K966J air compressor, lacked a cover plate or other means of sealing openings. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not provide a copy of the information in 29 CFR 1910.134 Appendix D to employees who voluntarily used 3M 8210V N95 respirators. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not use signs to identify the location of a fire extinguisher mounted on a column between the planer and molder machines. (b) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not use signs to identify the location of a fire extinguisher mounted on a column adjacent to the dust collection system fan. Access to this particular extinguisher was also impeded by the presence of a garbage can, a motor sitting on the floor, and two wooden shafts lying against the column. (c) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not use signs to identify the location of a fire extinguisher mounted on a column in the mezzanine about the dust collection system area. (d) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not use signs to identify the location of a fire extinguisher mounted on the wall adjacent to emergency exit doorway into the yard. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer had not developed a written hazard communication program despite having employees who were exposed to combustible wood dust and who used propane and lubricating oils to power and maintain machinery and forklifts. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer did not maintain copies of safety data sheets in the workplace despite having employees who were exposed to combustible wood dust and who used propane and lubricating oils to power and maintain machinery and forklifts. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about August 3, 2016, at 50-01 Rockaway Beach Boulevard, Far Rockaway, NY 11691 The employer had not provided hazard communication training to employees even though they were exposed to various hazardous substances including combustible wood dust, propane and lubricating oils. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SINGH HARDWOOD COMPANY, INC.
FAR ROCKAWAY, NY—2016-07-26 00:00:00
SINGH HARDWOOD COMPANY, INC.
View SINGH HARDWOOD COMPANY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
WALNUT GROVE, KY—2026-07-07
69295 - MENZNER HARDWOODS CO
DEERWOOD, MN—2026-07-02
111521 - ACORN MILLWORK INC
MONTELLO, WI—2026-06-30
FLOORING AND EQUIPMENT LLC
LENOIR, NC—2026-06-26
161438 - WOODGRAIN, INC.
SALEM, MO—2026-06-09
CANOAK MISSOURI, LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341668366.