Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRICFIL CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELECTRICFIL CORPORATION in 18831 CARTER CIRCLE, ELKMONT, AL 35620 (NAICS 336350). OSHA activity number 341676377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electricfil Corporation — free Get an email when a new federal OSHA severe-injury report for Electricfil Corporation is published. One employer, no account, unsubscribe in one click.
Site address
18831 CARTER CIRCLE
City
ELKMONT
State
AL
ZIP
35620
Mailing
18831 CARTER CIRCLE, ELKMONT, AL 35620
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336350
Employees
259
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 3 instances 3 exposed
Issued
Aug 25, 2016
Abate by
Mar 8, 2018
Penalty
Initial $12,471 · Current $9,750 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) On or about 08/01/2016 - Maintenance department, an employee performing electrical work on machinery such as, but not limited to, a Battenfield injection molding, TR-US 02 with 480 VAC , pneumatic pressure, and gravitational sources of energy was doing so without a specific procedure for locking and tagging out the machinery.     b) On or about 08/01/2016 - Maintenance department, an employee performing mechanical work on machinery such as, but not limited to, the potting machine with electrical, pneumatic, and gravitational sources of energy was doing so without a specific procedure for locking and tagging out the machinery.     c) On or about 08/01/2016 - Maintenance department, an employee performing maintenance work on machinery such as, but not limited to, the drill machinery with electrical and pneumatic sources of energy was doing so without a specific procedure for locking and tagging out the machinery.
Recent events (3)
  • — J (O) $9750
  • — C (S) $12471
  • — Z (S) $12471

1910.147 C07 I

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Aug 25, 2016
Abate by
Mar 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    a) On or about 08/01/2016 - Maintenance department, employees performing maintenance activities on machinery such as, but not limited to, the injection molding machine, potting machine, and drilling machine were not aware of the hazards while performing maintenance.
Recent events (3)
  • — J (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C05 I

Deleted Serious Gravity 10 3 instances 3 exposed
Issued
Aug 25, 2016
Abate by
Sep 7, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  a) On or about 08/01/2016 - Maintenance department, Battenfield injection molding machine, TR-US 02, employees performing maintenance on a DFE Valve with multiple sources of energy including 480 VAC, pneumatic pressure, and gravity were not provided adequate devices to ensure that he machinery could not be reenergized while employees performed maintenance.  b) On or about 08/01/2016 - Maintenance department, employees performing maintenance on machinery such as, but not limited to, the potting machine were not provided the adequate amount of devices to block, lock, or tagout the machinery operating on electrical, pneumatic, and gravitational sources of energy.   c) On or about 08/01/2016 - Maintenance department, an employee performing maintenance on machinery such as, but not limited to, a drill machine was not provided the adequate amount of devices to lock and tagout the machine operating on electrical power and pneumatic pressure.
Recent events (3)
  • — J (S) $0
  • — C (S) $12471
  • — Z (S) $12471

1910.178 L04 III

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2016
Abate by
Mar 8, 2018
Penalty
Initial $7,572 · Current $5,750 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    a) On or about 08/01/2016 - Maintenance department, an employee operating a Hyster 30 powered industrial truck, model #E40HSD2-21, serial #B219NO2101L, had not been evaluated since January 26, 2011.
Recent events (3)
  • — J (O) $5750
  • — C (S) $7572
  • — Z (S) $7572

1910.212 A01

Serious Gravity 5 5 instances 3 exposed
Issued
Aug 25, 2016
Abate by
Mar 8, 2018
Penalty
Initial $9,086 · Current $5,750 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about 08/01/2016 - Maintenance cage, a MSC drill press model #00085420, serial #433206 was being operated with an unguarded rotating chuck.     b) On or about 08/01/2016 - Maintenance cage, a Vectrax milling and drilling machine model #00492108, serial #434151 was being operated with an unguarded rotating chuck.     c) On or about 08/01/2016 - Maintenance cage, a Trump vertical milling machine model #K3V1F, serial #K3V104 was being operated with an unguarded rotating chuck.     d) On or about 08/01/2016 - Maintenance cage, a 6-inch belt sander model #09514506, serial #036022 was being operated without a guard for the ingoing nip point.     e) On or about 08/01/2016 - Maintenance cage, a MSC horizontal band saw model #473260, serial #200407 was being operated with an unguarded rotating blade.
Recent events (3)
  • — J (S) $5750
  • — C (S) $9086
  • — Z (S) $9086

1910.333 A

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2016
Abate by
Mar 8, 2018
Penalty
Initial $7,572 · Current $3,786 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    a) On or about 08/01/2016 - Maintenance department, an employee calibrating a Battenfield injection molding machine TR-US-02, using a multi-meter was within 2-3 feet of a live 3 phase, 480 VAC electrical panel.
Recent events (3)
  • — J (O) $3786
  • — C (S) $7572
  • — Z (S) $7572

View Electricfil Corporation's full OSHA safety record →