On , OSHA opened an unprogrammed Other safety inspection of ROOFING R US SYSTEMS INC. in 612 ROBIN LANE, KISSIMMEE, FL 34759 (NAICS 238160). OSHA activity number 341677706.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOFING R US SYSTEMS INC.
- Site address
- 612 ROBIN LANE
- City
- KISSIMMEE
- State
- FL
- ZIP
- 34759
- Mailing
- PO BOX 950870, LAKE MARY, FL 32795
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 31, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the job site, employees removing roof shingles as part of re-roofing work on a 6 in 12 pitched roof, were exposed to an 8 foot 7 inch (from the edge of the roof to the ground) fall hazard, in that, fall protection was not used, on or about 08/05/2016.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- Jan 31, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about 08/05/2016, at the job site - the rails of the ladder used to access the roof did not extend at least 3 feet above the upper landing surface, exposing the employees to an 8 foot 7 inch fall hazard.
Recent events (1)
- — Z (S) $2716
1926.1053 B04
- Issued
- Jan 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about 08/05/2016, at the job site - an A-frame ladder that was closed and leaning against the wall was used by the employees to access the roof, exposing the employees to an 8 foot 7 inch fall hazard.
Recent events (1)
- — Z (S) $0
More inspections at Roofing R US Systems INC.
View Roofing R US Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341677706.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.