LAKEWOOD, CO —
OSHA Inspection: INTEGRATED SERVICE CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of INTEGRATED SERVICE CORPORATION in 12500 W CEDAR DR, LAKEWOOD, CO 80228 (NAICS 811121). OSHA activity number 341678498.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTEGRATED SERVICE CORPORATION
- Site address
- 12500 W CEDAR DR
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80228
- Mailing
- 12500 W CEDAR DR, LAKEWOOD, CO 80228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 16
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 D03 III B 2
- Issued
- Sep 21, 2016
- Abate by
- Oct 3, 2016
- Penalty
- Initial $5,345 · Current $750 Reduced
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an ESLI that would ensure cartridges were changed before the end of their service life: a) On or about August 5, 2016, and at times prior, and at times prior, the employer did not protect employees that used half-face air purifying respirators while spray-applying coatings containing isocyanates and other hazardous chemicals by developing and implementing a cartridge change schedule to prevent breakthrough of the organic vapor cartridges used with the respirators. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (S) $750
- — C (S) $5345
- — Z (S) $5345
1910.215 A04
- Issued
- Sep 21, 2016
- Abate by
- Sep 27, 2016
- Penalty
- Initial $7,126 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about August 5, 2016, and at times prior, the employer exposed employees to stuck-by hazards due to the bench grinder work rest(s), located in the automotive bay area, not being adjusted to one eighth inch on the left side. The right side grinding wheel did not have a work rest in place. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (S) $0
- — C (S) $7126
- — Z (S) $7126
1910.215 B09
- Issued
- Sep 21, 2016
- Abate by
- Sep 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On August 5, 2016, the employer exposed employees in the automotive bay area to struck-by hazards due to bench grinder tongue guards exceeding one fourth inch. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Sep 21, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $5,345 · Current $750 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) On or about August 5 2016, and at times prior, employees were exposed to fire and explosion hazards in that the employer did not store the oxygen cylinders 20 feet away from acetylene cylinders and other combustible materials, such as paper in the trashcan. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (S) $750
- — C (S) $5345
- — Z (S) $5345
1910.22 A01
- Issued
- Sep 21, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. (a) On or about August 5, 2016, the employer did not keep the automotive repair area free from accumulation of materials, which could cause trips, slips and fall hazards. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Sep 21, 2016
- Abate by
- Oct 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On or about August 5, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the autobody shop area, had not been inspected since 2014. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Sep 21, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) On or about August 5, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the autobody shop area, had not been inspected since 2014. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.212 B
- Issued
- Sep 21, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or about August 5, 2016, and at times prior, employees were exposed to injuries in that the Central machinery 6" bench grinder, located in the auto body area, was not anchored. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Sep 21, 2016
- Abate by
- Sep 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about August 5, 2016, the employer did not maintain a clear distance of 3 feet in front of the circuit breaker panels and transformers in order to provide access for emergency maintenance. Abatement Note: Abatement certification is not required for this item.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.305 B01 I
- Issued
- Sep 21, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: (a) On or about August 5, 2016, and times prior, employees were exposed to electrical injuries in that the electrical pendant box, located on the North wall in the automotive shop area, was missing a knockout. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in CO
Source