On , OSHA opened a planned health inspection of INTEGRATED SERVICE CORPORATION in 12500 W CEDAR DR, LAKEWOOD, CO 80228 (NAICS 811121). OSHA activity number 341678498.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Integrated Service Corporation — free Get an email when a new federal OSHA severe-injury report for Integrated Service Corporation is published. One employer, no account, unsubscribe in one click.
Site address
12500 W CEDAR DR
City
LAKEWOOD
State
CO
ZIP
80228
Mailing
12500 W CEDAR DR, LAKEWOOD, CO 80228
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
16
Ownership type
A

10 citations on file for this inspection.

1910.134 D03 III B 2

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 21, 2016
Abate by
Oct 3, 2016
Penalty
Initial $5,345 · Current $750 Reduced
29 CFR 1910.134(d)(3)(iii)(B)(2):  The employer did not implement a change schedule for respirators not equipped with an ESLI that would ensure cartridges were changed before the end of their service life:       a)  On or about August 5, 2016, and at times prior, and at times prior, the employer did not protect employees that used half-face air purifying respirators while spray-applying coatings containing isocyanates and other hazardous chemicals by developing and implementing a cartridge change schedule to prevent breakthrough of the organic vapor cartridges used with the respirators.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $750
  • — C (S) $5345
  • — Z (S) $5345

1910.215 A04

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Sep 21, 2016
Abate by
Sep 27, 2016
Penalty
Initial $7,126 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) On or about August 5, 2016, and at times prior, the employer exposed employees to stuck-by hazards due to the bench grinder work rest(s), located in the automotive bay area, not being adjusted to one eighth inch on the left side.  The right side grinding wheel did not have a work rest in place.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $7126
  • — Z (S) $7126

1910.215 B09

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Sep 21, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) On August 5, 2016, the employer exposed employees in the automotive bay area to struck-by hazards due to bench grinder tongue guards exceeding one fourth inch.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Sep 29, 2016
Penalty
Initial $5,345 · Current $750 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)  On or about August 5 2016, and at times prior, employees were exposed to fire and explosion hazards in that the employer did not store the oxygen cylinders 20 feet away from acetylene cylinders and other combustible materials, such as paper in the trashcan.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $750
  • — C (S) $5345
  • — Z (S) $5345

1910.22 A01

Other-than-serious 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Sep 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  (a)  On or about August 5, 2016, the employer did not keep the automotive repair area free from accumulation of materials, which could cause trips, slips and fall hazards.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a)  On or about August 5, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the autobody shop area, had not been inspected since 2014.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Sep 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a)  On or about August 5, 2016, the employer exposed employees to a fire hazard in that the portable fire extinguishers, located in the autobody shop area, had not been inspected since 2014.   Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 8 exposed
Issued
Sep 21, 2016
Abate by
Sep 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  (a)  On or about August 5, 2016, and at times prior, employees were exposed to injuries in that the Central machinery 6" bench grinder, located in the auto body area, was not anchored.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Sep 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  On or about August 5, 2016, the employer did not maintain a clear distance of 3 feet in front of the circuit breaker panels and transformers in order to provide access for emergency maintenance.  Abatement Note: Abatement certification is not required for this item.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 B01 I

Other-than-serious 1 instance 16 exposed
Issued
Sep 21, 2016
Abate by
Sep 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  (a) On or about August 5, 2016, and times prior, employees were exposed to electrical injuries in that the electrical pendant box, located on the North wall in the automotive shop area, was missing a knockout.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341678498.