GULFPORT, MS —
OSHA Inspection: PICKERS CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PICKERS CONSTRUCTION in 530 W. BEACH BLVD., GULFPORT, MS 39501 (NAICS 236115). OSHA activity number 341681484.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PICKERS CONSTRUCTION
- Site address
- 530 W. BEACH BLVD.
- City
- GULFPORT
- State
- MS
- ZIP
- 39501
- Mailing
- 502 SUNSET DR., BAY SAINT LOUIS, MS 39520
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B02
- Issued
- Aug 31, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $3,367 · Current $206 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: (a) Inside garage - On or about August 5, 2016 an employee attaching the second floor rafters from a a 2 inch X 8 inch wood walk plank was exposed to a fall hazard.
Recent events (3)
- — F (S) $206.25
- — C (S) $3367
- — Z (S) $3367
1926.451 G01
- Issued
- Aug 31, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $3,367 · Current $206 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) Inside Garage - On or about August 5, 2016 employee working from self made wood scaffolding attaching second floor rafters 12 feet high was not protected from falling with the use of fall protection or railings.
Recent events (3)
- — F (S) $206.25
- — C (S) $3367
- — Z (S) $3367
1926.501 B13
- Issued
- Aug 31, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $3,367 · Current $206 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Top of second level house - On or about August 5, 2016 employees installing second floor joist boards were 19 feet high without having any fall protection.
Recent events (3)
- — F (S) $206.25
- — C (S) $3367
- — Z (S) $3367
1926.1053 B01
- Issued
- Aug 31, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $3,367 · Current $206 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) Inside Garage east wall - On or about August 5, 2016 an employee was using an aluminum folding ladder that did not reach the top of the 13 foot side wall to gain access to and from the upper level.
Recent events (3)
- — F (S) $206.25
- — C (S) $3367
- — Z (S) $3367
1910.178 L
- Issued
- Aug 31, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l): At this jobsite, the employer had not assured that the forklift operators were competent to operate the JLG N77592 forklift, which was being used to transport and place wood framing material on the upper floors, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). (a) West side of house - On or about August 5, 2016 an employee was operating the JLG N77592 rough terrain fork lift to supply material to the workers on the second floor with out having received any training on the save operations of fork lifts.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.405 G02 III
- Issued
- Aug 31, 2016
- Abate by
- Sep 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: (a) West side of building - On or about August 5, 2016 The ROLAIR air compressor electrical cord has been spliced at the plug end using standard black electrical tape to cover the wires that does not meet the insulation of the outer sheathing.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Pickers Construction
View Pickers Construction's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341681484.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.