MONTICELLO, GA —
OSHA Inspection: PERMATHERM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PERMATHERM, INC. in 269 INDUSTRIAL PARK DRIVE, MONTICELLO, GA 31064 (NAICS 326140). OSHA activity number 341682862.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERMATHERM, INC.
- Site address
- 269 INDUSTRIAL PARK DRIVE
- City
- MONTICELLO
- State
- GA
- ZIP
- 31064
- Mailing
- 269 INDUSTRIAL PARK ROAD, MONTICELLO, GA 31064
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326140
- Employees
- 48
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 21, 2016
- Abate by
- Nov 9, 2016
- Penalty
- Initial $8,730 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about 8/9/2016 in the production area at 269 Industrial Park Drive, Monticello, GA: Employers energy control procedures for their machines and equipment were not clear, specific, and did not address steps to safely de-energize all of the energy sources such as but not limited to electrical, pneumatic, steam, heat, and mechanical. Energy sources approximate gravity ratings: Electrical voltage up to 240 volts, Pneumatic up to 60 psi, Heat up to 138 degree Fahrenheit, and Steam up to 200 degrees Fahrenheit: Machines and Equipment: A.10 Combination Cutters A.2 Down Cutter #2 A.12 Down Cutter A.8 Slabber #1 A.11 Slabber #2 A.1 Electric Eye Cutter #1 A.9 Densifier A.13 Slabber #3 A.15 Dust Collector #1 E.34 Hirsch Prex 9000 Expander E.25 Doe Kong Block Molder
Recent events (2)
- — I (S) $4800
- — Z (S) $8730
1910.147 C06 I
- Issued
- Oct 21, 2016
- Abate by
- Nov 9, 2016
- Penalty
- Initial $8,730 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 8/9/2016 in the production area at 269 Industrial Park Drive, Monticello, GA: The employer did not perform annual periodic inspection on the equipment that the employees were required to perform maintenance, repairs, services, adjustments, setup, and clean. Machines and Equipment: A.10 Combination Cutters A.2 Down Cutter #2 A.12 Down Cutter A.8 Slabber #1 A.10 Down Cutter #2 A.11 Slabber #2 A.1 Electric Eye Cutter #1 A.7 Down Cutter #1 A.9 Densifier A.13 Slabber #3 A.15 Dust Collector #1 E.34 Hirsch Prex 9000 Expander E.25 Doe Kong Block Molder
Recent events (2)
- — I (S) $4800
- — Z (S) $8730
1910.212 A01
- Issued
- Oct 21, 2016
- Abate by
- Nov 9, 2016
- Penalty
- Initial $8,730 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 8/9/2016 at the foam cutting machines in the production area at 269 Industrial Park Drive, Monticello, GA: Employees operating the foam cutting machines with the heated metal wires used to make the vertical and horizontal cuts to the foam material were exposed to temperature up to 138 degrees Fahrenheit. The employer failed to guard the heated wire while the employees were removing the access foam or working near the connected areas of the machine. Machines and Equipment: A.1 Eye Cutter #1 A.2 Down Cutter #2 A.7 Down Cutter #1 A.8 Slabber #1 A.10 Down Cutter #2 A.10 Blue Combination Cutter #2 A.11 Slabber #2 A.12 Down Cutter #3 A.13 Slabber #3
Recent events (2)
- — I (S) $4800
- — Z (S) $8730
1910.303 G02 I
- Issued
- Oct 21, 2016
- Abate by
- Nov 9, 2016
- Penalty
- Initial $8,730 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about 8/9/2016 at the blue horizontal and vertical foam cutting machine labeled A10 in the production area at 269 Industrial Park Drive, Monticello, GA: Employees operating the cutter machine were exposed to approximately 120 volts on the unguarded metal sections of the machine. An employee was hospitalized from the electrical shock he sustained from the unguarded metal section on 8/2/2016.
Recent events (2)
- — I (S) $4800
- — Z (S) $8730
More inspections at Permatherm, INC.
View Permatherm, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326140)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341682862.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.