CINCINNATI, OH —
OSHA Inspection: BM CUSTODIO PAINTING & CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BM CUSTODIO PAINTING & CONSTRUCTION, LLC in 9189 COLERAIN AVE, CINCINNATI, OH 45251 (NAICS 238320). OSHA activity number 341683035.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BM CUSTODIO PAINTING & CONSTRUCTION, LLC
- Site address
- 9189 COLERAIN AVE
- City
- CINCINNATI
- State
- OH
- ZIP
- 45251
- Mailing
- 6655 SARAZEN CT, FLORENCE, KY 41042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 2
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B01
- Issued
- Sep 28, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $3,741 · Current $1,871 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Located on the north side of a commercial exterior structure, an employee was observed standing at the edge of a low pitch roof overhang painting the exterior commercial structure while not utilizing any fall protection system. Potential fall height was measured in greater than 11 feet with roof pitch of 2 in 12. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1870.5
- — Z (S) $3741