WALES, ME —
OSHA Inspection: MASON PALLET, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of MASON PALLET, INC. in 358 LEEDS JUNCTION ROAD, WALES, ME 04280 (NAICS 321920). OSHA activity number 341683266.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASON PALLET, INC.
- Site address
- 358 LEEDS JUNCTION ROAD
- City
- WALES
- State
- ME
- ZIP
- 04280
- Mailing
- 233 STRICKLAND LOOP, LIVERMORE FALLS, ME 04254
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 15
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.95 C01
- Issued
- Jan 6, 2017
- Abate by
- Mar 14, 2017
- Penalty
- Initial $5,487 · Current $2,743 Reduced
81108111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: The employer did not develop and implement an effective hearing conservation program when employee noise exposures exceeded an 8-hour time weighted average sound level of 85 decibels, in the following instances: a) Facility - An employee assembling pallets had an 8-hour time weighted average of 87.7 decibels. b) Facility - An employee assembling pallets had an 8-hour time weighted average of 88.3 decibels. c) Facility - An employee assembling pallets had an 8-hour time weighted average of 89.5 decibels. d) Facility - An employee operating the pallet dismantler had an 8-hour time weighted average of 94.8 decibels.
Recent events (2)
- — I (S) $2743
- — Z (S) $5487
1910.147 C01
- Issued
- Jan 6, 2017
- Abate by
- Mar 14, 2017
- Penalty
- Initial $5,487 · Current $2,743 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: At the Facility - The employer did not establish an energy control program for equipment at the facility, such as but not limited to, the two SmartProducts One Man Pallet Dismantlers.
Recent events (2)
- — I (S) $2743
- — Z (S) $5487
1910.147 D04 I
- Issued
- Jan 6, 2017
- Abate by
- Mar 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: Pallet Dismantling Area - No lockout/tagout devices were affixed to the 64" One-Man Pallet Dismantler that had a 240 volt 3 phase electrical disconnect and 1500 p.s.i./1700 p.s.i. hydraulic manual pump.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Jan 6, 2017
- Abate by
- Jan 19, 2017
- Penalty
- Initial $7,839 · Current $3,919 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: Wooden pallets were not stacked or limited in height to secure against sliding and collapse, in the following instances: a) Along the right segment at the Y of the roadway - An unsecured stack of pallets collapsed. b) Front side of employee parking area - Pallets were not stable and secure against sliding and collapse. c) Adjacent to employee entrance walkway - Pallets were stacked unevenly approximately 12' high. Mason Pallet, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.176(b), which was contained in OSHA inspection number 1113688, citation number 1, item number 2 and was affirmed as a final order on 04/19/2016, with respect to a workplace located at Wales, ME.
Recent events (2)
- — I (R) $3919
- — Z (R) $7839
1910.303 G01 II
- Issued
- Jan 6, 2017
- Penalty
- Initial $4,704 · Current $2,352 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: Pallet Dismantling Area - The working space for the 240 volt 3 phase electrical disconnect for the 64" One-Man Pallet Dismantler was used for the storage of two large scrap-wood bins. Mason Pallet, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.303(g)(1)(ii), which was contained in OSHA inspection number 1113688, citation number 2, item number 1 and was affirmed as a final order on 04/19/2016, with respect to a workplace located at Wales, ME.
Recent events (2)
- — I (R) $2352
- — Z (R) $4704
1910.157 E03
- Issued
- Jan 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Portable fire extinguishers were not subjected to an annual maintenance check, in the following instances: a) Entrance to main building - The portable fire extinguisher was not subjected to an annual maintenance check since 2009. b) Inside garage - The portable fire extinguisher was not subjected to an annual maintenance check since 2004.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B07 IV
- Issued
- Jan 6, 2017
- Abate by
- Jan 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: Quonset Assembling Area - The electrical metallic tubing was separated at the connector exposing three insulated conductors.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Jan 6, 2017
- Abate by
- Mar 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Facility - The employer did not develop or implement a written hazard communications program for their employees who use Touch-n-Tone and Rust-oleum spray paints, lubricants, and LP Gas.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mason Pallet, INC.